Estimation of uranium concentration in Indian monazite samples by using HPGe semiconductor detector
H B Shrivastava1, N Rupa Rita1, V Koteswara Rao1
1Atomic Minerals Directorate for Exploration and Research, Begumpet, Hyderabad, India.
Abstract:
Various techniques are available for the estimation of uranium concentration in geological rock samples. In the uranium exploration program in India, the beta-gamma technique is widely used by the Atomic Minerals Directorate for Exploration and Research (Department of Atomic Energy) to estimate uranium concentration in natural rock or soil samples. Uranium concentration cannot be estimated accurately by the beta-gamma technique if the sample has high concentrations of thorium. Because the ratio of thorium to uranium concentration varies between 15 and 30 in monazite samples, uranium concentration in monazite samples cannot be estimated accurately by the conventional beta-gamma technique. Uranium concentration in monazite samples can be estimated by measuring the 1.001 MeV gamma ray peak of Pa-234 (which is a decay product of uranium having a half-life of 1.17 min) using a P-type HPGe semiconductor detector. In this paper, uranium concentrations in 10 samples of Indian monazites were estimated using the P-type HPGe semiconductor detector, in which the average thorium concentration was 9.5%.
Related Concept Videos
Semiconductors
Metals such as copper (Cu), zinc (Zn), or lead (Pb) have low resistivity and feature conduction bands that are either not fully occupied or overlap with the valence band, making a bandgap non-existent. This allows electrons in the highest energy levels of the valence band to easily transition to the conduction band upon gaining...
Types of Semiconductors
Metal-Semiconductor Junctions
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Concentration Cells
Consider the following voltaic cell:
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...