Related Experiment Video
Updated: Feb 6, 2026

Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot Heater System
Published on: August 7, 2018
Conducting Elevated Temperature Normal and Combined Pressure-Shear Plate Impact Experiments Via a Breech-end Sabot
Bryan Zuanetti1, Tiaxue Wang1, Vikas Prakash2
1Department of Mechanical and Aerospace Engineering, Case Western Reserve University.
Abstract:
A novel approach for conducting normal and/or combined pressure-shear plate impact experiments at test temperatures up to 1000 °C is presented. The method enables elevated temperature plate-impact experiments aimed towards probing dynamic behavior of materials under thermomechanical extremes, while mitigating several special experimental challenges faced while performing similar experiments using the conventional plate impact approach. Custom adaptations are made to the breech-end of a single-stage gas-gun at Case Western Reserve University; these adaptations include a precision-machined extension piece made from SAE 4340 steel, which is strategically designed to mate the existing gun-barrel while providing a high tolerance match to the bore and keyway. The extension piece contains a vertical cylindrical heater-well, which houses a heater assembly. A resistive coil heater-head, capable of reaching temperatures of up 1200 °C, is attached to a vertical stem with axial/rotational degrees of freedoms; this enables thin metal specimens held at the front-end of a heat-resistant sabot to be heated uniformly across the diameter to the desired test temperatures. By heating the flyer plate (in this case, the sample) at the breech-end of the gun-barrel instead of at the target-end, several critical experimental challenges can be averted. These include: 1) severe changes in the alignment of the target plate during heating due to the thermal expansion of the several constituents of the target holder assembly; 2) challenges that arise due to the diagnostics elements, (i.e., polymer holographic gratings, and optical probes) being too close to the heated target assembly; 3) challenges that arise for target plates with an optical window, where crucial tolerances between the sample, bond layer, and window become increasingly difficult to maintain at high temperatures; 4) in the case of combined compression-shear plate impact experiments, the need for high-temperature resistant diffraction gratings for the measurement of transverse particle velocity at the free surface of the target; and 5) limitations imposed on the impact velocity necessary for unambiguous interpretation of the measured free surface velocity versus time profile due to thermal softening and possibly yielding of the bounding target plates.By utilizing the adaptations mentioned above, we present results from a series of reverse geometry normal plate impact experiments on commercial purity aluminum at a range of sample temperatures. These experiments show decreasing particle velocities in the impacted state, which are indicative of material softening (decrease in post-yield flow stress) with increasing sample temperatures.
Related Concept Videos
Normal and Shear Force
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Fluid Pressure over Curved Plate of Constant Width

