Related Experiment Video
Updated: Feb 6, 2026

In Vitro Apical-Out Enteroid Model of Necrotizing Enterocolitis
Published on: June 8, 2022
A Comparative Evaluation of Apical Leakage using Three Root Canal Sealants: An in vitro Study
Punkit S Sudan1, Emmanuel P Samson2, Maneet K Kukreja3
1Birmingham, West Midlands, UK.
Aim:
Apical leakage is one of the drawbacks leading to endodontic failure. Various root canal sealants have been tried in endodontics. The present study was conducted to compare root canal sealants such as Endorez, Realseal, and Metaseal in preventing apical leakage.
Materials And Methods:
Sixty mandibular single-canal premolars were divided into three groups of 20 each. Group I teeth were sealed with Endorez, group II teeth with Realseal, and group III teeth with Metaseal. After completing endodontic treatment in all teeth and sealing with above sealants, glucose leakage value was assessed at 1st, 8th, and 15th day.
Results:
At day 1 [mean ± standard deviation (SD)], leakage was 0.416 ± 0.011 in group I, 0.234 ± 0.09 in group II, and 0.328 ± 0.19 in group III. On 8th day, it was 2.124 ± 0.108 in group I, 0.624 ± 0.102 in group II, and 1.31 ± 0.24 in group III. On 15th day, it was 5.178 ± 0.125 in group I, 3.122 ± 0.150 in group II, and 4.25 ± 0.28 in group III. The mean apical leakage in all groups in different days was statistically significant (p < 0.05).
Conclusion:
Endorez sealant showed highest apical leakage, whereas Realseal had minimum leakage. There was significant increase in leakage in all groups with the progression of time.
Clinical Significance:
With the advent of different root canal sealants, the success rate of the root canal-treated teeth can be confirmed.
Related Concept Videos
Primary and Secondary Growth in Roots and Shoots
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...