Related Experiment Video
Updated: Feb 6, 2026

Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Magnetic Resonance Imaging for Quantitative Assessment of Lung Aeration: A Pilot Translational Study
Lorenzo Ball1,2,3,4, Anja Braune1, Peter Spieth1
1Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.
Abstract:
Background: Computed tomography is the gold standard for lung aeration assessment, but exposure to ionizing radiation limits its application. We assessed the ability of magnetic resonance imaging (MRI) to detect changes in lung aeration in ex vivo isolated swine lung and the potential of translation of the findings to human MRI scans. Methods: We performed MRI scans in 11 isolated non-injured and injured swine lungs, as well as 6 patients both pre- and post-operatively. Images were obtained using a 1.5 T MRI scanner, with T1 - weighted volumetric interpolated breath-hold examination (VIBE) and T2 - weighted half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences. We scanned swine lungs, with reference samples of water and muscle, at different airway pressure levels: 0, 40, 10, 2 cmH2O. We investigated the relations between MRI signal intensity and both lung density and gas content fraction. We analyzed patients' images according to the findings of the ex vivo model. Results: In the ex vivo samples, the lung T1 - VIBE signal intensity normalized to water or muscle reference signal correlated with lung density (r2 = 0.98). Thresholds for poorly and non-aerated lung tissue, expressed as MRI intensity attenuation factor compared to the deflated lung, were estimated as 0.70 [95% CI: 0.65-0.74] and 0.28 [95% CI: 0.27-0.30], respectively. In patients, dorsal versus ventral regions had a higher MRI signal intensity both pre- and post-operatively (p = 0.031). Comparing post- versus pre-operative scans, lung volume decreased (p = 0.028), while the following increased: MRI signal intensity in ventral (p = 0.043) and dorsal (p < 0.0001) regions, and percentages of non-aerated (p = 0.028) and poorly aerated tissue volumes (p = 0.028). Conclusion: Magnetic resonance imaging signal intensity is a function of lung density, decreasing linearly with increasing gas content. Lung MRI might be useful for estimating lung aeration. Compared to CT, this technique is radiation-free but requires a longer acquisition time and has a lower spatial resolution.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Pilot and Numeric Relaying
Translation
Translation is the process of synthesizing proteins from the genetic information carried by messenger RNA (mRNA). Following transcription, it constitutes the final step in the expression of genes. This process is carried out by ribosomes, complexes of protein and specialized RNA molecules. Ribosomes, transfer RNA (tRNA), and other proteins produce a chain of amino acids—the polypeptide—as the end product of translation.
Translation Produces the Building Blocks of...

