Related Experiment Video
Updated: Feb 6, 2026

Particle Image Velocimetry Investigation of Hemodynamics via Aortic Phantom
Published on: February 25, 2022
Sinus Hemodynamics Variation with Tilted Transcatheter Aortic Valve Deployments.
Hoda Hatoum1, Jennifer Dollery2, Scott M Lilly3
1Department of Biomedical Engineering, The Ohio State University, 473 W 12th Ave., Columbus, OH, 43210, USA.
Transcatheter aortic valve replacement (TAVR) axis misalignment can cause sinus flow stasis and increase leaflet thrombosis risk. Tilted valve positions, especially away from the sinus, worsen blood washout and flow dynamics.
Area of Science:
- Cardiovascular Engineering
- Biomedical Fluid Dynamics
- Medical Device Technology
Background:
- Leaflet thrombosis is a known complication of transcatheter aortic valve replacement (TAVR).
- Sinus hemodynamics, including shear stress and washout, are critical for preventing thrombus formation on TAV leaflets.
- The impact of TAV axis misalignment on sinus hemodynamics and thrombosis risk is not well understood.
Purpose of the Study:
- To investigate the effect of TAV angular misalignment relative to the aortic root axis on sinus flow stasis.
- To determine how TAV axis misalignment influences hemodynamics, potentially leading to leaflet thrombosis.
Main Methods:
- In vitro assessment of sinus hemodynamics using particle-image velocimetry in a 3D printed aortic root model.
- Implantation of an Edwards SAPIEN3 TAV in three angular misalignment conditions: untilted, tilted towards the sinus, and tilted away from the sinus.
- Calculation of TAV hemodynamics, sinus vortex dynamics, leaflet shear stress, and sinus blood washout time.
Main Results:
- No significant difference in pressure gradients was observed between groups.
- Both tilted TAV positions showed significantly reduced blood velocity and vorticity in the sinuses.
- Decreased shear stress probability near leaflets in tilted positions indicates increased stasis.
- TAV tilted away from the sinus presented the most unfavorable scenario with significantly poorer washout.
Conclusions:
- TAV angular misalignment significantly alters sinus hemodynamics, reducing velocity and vorticity.
- Misalignment increases the risk of sinus flow stasis and potentially leaflet thrombosis.
- TAV axis alignment is a crucial factor influencing leaflet thrombosis risk by modifying sinus hemodynamics.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...