KPS Bipolar Radial Head Arthroplasty - Polyethylene Head Replacement with a Metal-covered Head. Case Study
Kamila Malesa1, Mariusz Urban1, Dariusz Michalik1
1Samodzielny Publiczny Szpital Kliniczny im. Prof. A. Grucy w Otwocku, Otwock, Polska / Gruca Orthopaedic and Trauma Teaching Hospital in Otwock, Poland Klinika Chirurgii Urazowej Narządu Ruchu i Ortopedii CMKP / Department of Traumatology and Orthopaedics, Centre of Postgraduate Medical Education.
Abstract:
Radial head replacement should be indicated in all cases of radial head fractures when open reduction and internal fixation is anticipated to be difficult or impossible. Although excellent therapeutic results have been ob-tained, this procedure, like any other surgical procedures, may be associated with severe complications, includ-ing contractures, ossification or aseptic synovitis. In these cases, removal of the prosthetic radial head has al-ways been a safe and popular solution producing a satisfactory clinical outcome. However, we present the case of a patient in whom the prosthesis was left in place, but the polyethylene head was replaced with a metal-covered head. The decision to perform this procedure was taken intraoperatively.
Related Concept Videos
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Bipolar Disorder
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...