A systematic approach for analysis and characterization of mispairing in bispecific antibodies with asymmetric

Chunlei Wang1, Bhargavi Vemulapalli1, Mingyan Cao1

  • 1a Department of Analytical Sciences , MedImmune, One Medimmune Way , Gaithersburg , MD , USA.

Mabs
|August 29, 2018
PubMed

Immunoglobulin G-like bispecific antibodies with asymmetric architecture are among the most widely used bispecific antibody formats for diagnostic and therapeutic applications. The primary technical challenge for this format is how to achieve correctly paired assembly of four unique polypeptide chains. Advances in protein engineering and process development are being used to overcome these challenges and are driving a corresponding demand for sensitive analytical tools to monitor and control mispaired species. Here, we report a systematic approach for analysis and characterization of mispairing in asymmetric bispecific antibodies. This approach consists of three orthogonal components, the first of which is a liquid chromatography (LC)-mass spectrometry (MS)-based method to measure the mass of intact antibodies. This method is used for fast analysis of mispairing and requires minimal method development, which makes it an ideal choice for early-stage development. The second component is a hydrophobic interaction chromatography (HIC)-based mispairing method that is suitable for lot release testing. The HIC method is robust and quality control friendly, and offers great linearity, precision, and accuracy. The third component is a two-dimensional LC-MS method for on-line chromatographic peak identification, which not only expedites this task but also reduces the risk of undesirable modifications during conventional fraction collection. These three methods dovetail to form the foundation of a complementary toolbox for analysis and characterization of mispairing in asymmetric bispecific antibodies and provide guidance and support for process development throughout the drug development life cycle.

Related Concept Videos

Chemical Equilibria: Systematic Approach to Equilibrium Calculations01:21

Chemical Equilibria: Systematic Approach to Equilibrium Calculations

Equilibrium calculations for systems involving multiple equilibria are often complex. For example, to calculate the solubility of a sparingly soluble salt in an aqueous solution in the presence of a common ion, one must consider all the equilibria in this solution. Calculations for these systems can be complicated and tedious, so a systematic approach with a series of steps is often helpful. The process is detailed below.
The first step is to identify all the chemical reactions involved, The...
1.6K
Rotation of Asymmetric Top01:11

Rotation of Asymmetric Top

By definition, a spherically symmetric body has the same moment of inertia about any axis passing through its center of mass. This situation changes if there is no spherical symmetry. Since most rigid bodies are not spherically symmetric, these require special treatment.
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
1.6K
Asymmetric Lipid Bilayer01:35

Asymmetric Lipid Bilayer

Biological membranes show uneven distribution of different types of lipids in the inner and outer layers, resulting in transverse asymmetric membranes. The treatment of the erythrocyte membrane with the enzyme phospholipase confirmed the asymmetric nature of the lipid bilayer. The enzyme hydrolyzes lipids into fatty acids and hydrophilic groups. The phospholipase acts only on the outer layer of the membrane, while the inner layer remains intact. The phospholipase treatment resulted in 80%...
9.9K
Random and Systematic Errors01:20

Random and Systematic Errors

Scientists always try their best to record measurements with the utmost accuracy and precision. However, sometimes errors do occur. These errors can be random or systematic. Random errors are observed due to the inconsistency or fluctuation in the measurement process, or variations in the quantity itself that is being measured. Such errors fluctuate from being greater than or less than the true value in repeated measurements. Consider a scientist measuring the length of an earthworm using a...
15.1K
Systematic Sampling Method01:17

Systematic Sampling Method

Sampling is a technique to select a portion (or subset) of the larger population and study that portion (the sample) to gain information about the population. Data are the result of sampling from a population. The sampling method ensures that samples are drawn without bias and accurately represent the population. Because measuring the entire population in a study is not practical, researchers use samples to represent the population of interest.
Systematic sampling is one of the simplest methods...
13.3K
Polymer Classification: Architecture01:14

Polymer Classification: Architecture

Polymers are classified as linear or branched on the basis of their chain architecture. The polymer chains in linear polymers have a long chain-like structure with minimal to no branching at all. Even if a polymer features large substituent groups on the monomer, which appear as branches to the skeleton, it is not considered a branched polymer. A branched polymer contains secondary polymer chains that arise from the main polymer chain. The branching occurs when the polymer growth shifts from...
3.9K