Clinical Leaflet Thrombosis in Transcatheter and Surgical Bioprosthetic Aortic Valves by Four-Dimensional Computed
Sukhdeep S Basra1, Ambarish Gopal2, Katie R Hebeler2
1Center for Advanced Heart Failure, University of Texas McGovern Medical School at Houston, Houston, Texas.
Background:
The incidence of leaflet thrombosis after transcatheter aortic valve replacement (TAVR) with active surveillance by four-dimensional computed tomography (4DCT) ranges from 7% to 14%. The incidence of leaflet thrombosis when 4DCT is performed for clinical and echocardiographic indications is unknown.
Methods:
All patients with prior TAVR or surgical aortic valve replacement (SAVR) who underwent evaluation between October 2015 and January 2017 at our institution and had clinical or echocardiographic indications of leaflet thrombosis were evaluated by 4DCT. Indications for 4DCT by echocardiography included (1) interval increase in mean gradient of 10 mm Hg or more, (2) interval decrease in ejection fraction of 10% or more, (3) thrombus seen on transthoracic echocardiography, (4) persistent or increasing paravalvular leak, or (5) valve dehiscence or thickened leaflets seen on transthoracic echocardiography. Clinical indicators were (1) stroke, (2) transient ischemic attack, or (3) new or worsening heart failure.
Results:
During the study period, 612 patients underwent TAVR, and 101 patients (55 TAVR; 46 SAVR) met the criteria for 4DCT imaging. Leaflet thrombosis was seen in 17 of 55 TAVR patients (30.9%) and 15 of 46 SAVR patients (32.6%). Follow-up imaging with 4DCT after treatment with anticoagulation showed improvement or resolution in thrombus burden and leaflet excursion in all TAVR patients and in two-thirds of SAVR patients.
Conclusions:
One-third of patients with clinical or echocardiographic indications suggestive of leaflet thrombosis were found to have evidence of leaflet thrombosis using 4DCT. This allowed tailored anticoagulation therapy with resolution of the thrombus in most patients and avoiding unnecessary anticoagulation in the remaining two-thirds of patients.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Venous Thrombosis I: Introduction
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...