Related Experiment Video
Updated: Feb 6, 2026

Evaluating the Effect of Roadside Parking on a Dual-Direction Urban Street
Published on: January 20, 2023
Identification of urban park activity intensity at different thermal environments and visible sky by using sound
1Program of Landscape and Recreation, National Chung Hsing University, 145 Xingda Rd, Taichung, 402, Taiwan.
Abstract:
An efficient urban environmental design considers appropriate thermal comfort condition, shaded space, and activity intensity. Physiologically equivalent temperature (PET) and visible sky, i.e., the sky view factor (SVF), are usually used as indicators to determine the outdoor thermal comfort and amount of shaded space, respectively. The activity intensity in urban parks, which is dependent on culture and micrometeorological conditions, was represented inappropriately by attendance density in Taiwan. To optimize the park design and improve the park utilization rate in Taiwan, several environmental factors such as sound pressure levels and numbers of park visitors were measured, and PET values and SVF values were calculated from primary micrometeorological data such as wind speed and globe temperature. This study proposed equivalent continuous sound pressure level (Leq) as a novel indicator to represent park activity intensity and investigated the correlation between Leq and SVF at different PET values. Leq was more appropriate than was attendance density in representing the park activity intensity in Taiwan. In addition, Leq was highly negatively correlated with SVF when visitors felt that the outdoor thermal comfort condition was hot or very hot. In other words, a lower degree of shading in the park resulted in lower activity intensity. Park visitors tended to engage in activities in the shaded regions because of more favorable thermal comfort conditions (i.e., neutral PET). The established quantitative relationships among Leq, PET, and SVF can serve as a reference for park planning.
More Related Videos
08:25Combining Eye-tracking Data with an Analysis of Video Content from Free-viewing a Video of a Walk in an Urban Park Environment
Published on: May 7, 2019
05:59Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
Published on: March 7, 2019
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Sound Intensity
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive...
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
Cycloaddition Reactions: MO Requirements for Thermal Activation
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...