Related Experiment Video
Updated: Feb 6, 2026

Structural Studies of Macromolecules in Solution using Small Angle X-Ray Scattering
Published on: November 5, 2018
Structure Determination of Phosphoric Acid and Phosphate Ions in Aqueous Solution Using EXAFS Spectroscopy and Large
Ingmar Persson1, Mylène Trublet2, Wantana Klysubun3
1Department of Molecular Sciences , Swedish University of Agricultural Sciences , P.O.Box 7015, SE-750 07 Uppsala , Sweden.
Abstract:
The structures of hydrated phosphoric acid and phosphate ions (H2PO4-, HPO42-, and PO43-) in aqueous solution have been determined by P K-edge EXAFS and large angle X-ray scattering (LAXS). The P-O bond distance in all phosphate species studied is close to 1.53 Å. The P-(O)···Oaq distances have been refined to ca. 3.6 Å from the LAXS data giving a P-O···Oaq bond angle close to tetrahedral, suggesting that each oxygen or OH group of phosphoric acid and dihydrogen phosphate, on average, hydrogen bind three water molecules. The (P-)O(-H)···Oaq and (P-)O···(H-)Oaq hydrogen bonds in hydrated phosphoric acid and the H2PO4- ion are shorter than the hydrogen bonds in neat water. This supports previous infrared spectroscopic studies claiming that the hydrogen bonds in hydrated phosphoric acid and phosphate ions are stronger than the hydrogen bonds in neat water. Phosphoric acid and phosphate ions can therefore be regarded as structure making solutes. This is the first study applying transmission mode X-ray absorption spectroscopy (XAS) data collection on the P K-edge. It shows that XAS spectra collected in transmission mode have a much better S/N ratio than data collected in fluorescence mode, allowing accurate determination of P-O bond distances. Furthermore, P K-edge EXAFS data collected in fluorescence mode display a higher amplitude at high k than expected due to increasing radiated volume of the sample with increasing energy as the total absorption decreases sharply with increasing energy of the X-rays. As a result, the fluorescence signal becomes nonproportional to the intensity of the X-ray beam over the EXAFS spectrum. This results in an increasing amplitude of the EXAFS function with increasing energy of the X-ray beam resulting in too small Debye-Waller coefficients.
More Related Videos
07:55Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
09:15Combining X-Ray Crystallography with Small Angle X-Ray Scattering to Model Unstructured Regions of Nsa1 from S. Cerevisiae
Published on: January 10, 2018
Related Concept Videos
Chemical Reactions in Aqueous Solutions
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...
Determining the pH of Salt Solutions
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):
Weak Acid Solutions
Strong Acid and Base Solutions