Palpable Breast Lump Triage by Minimally Trained Operators in Mexico Using Computer-Assisted Diagnosis and Low-Cost
Susan M Love1, Wendie A Berg1, Christine Podilchuk1
1Susan M. Love and Leah Eshraghi, Dr Susan Love Research Foundation, Encino, CA; Wendie A. Berg, Magee-Womens Hospital, University of Pittsburgh School of Medicine, Pittsburgh, PA; Christine Podilchuk, Krishnamohan Pathicherikollamparambil, Ananth Sankarasubramanian, and Richard Mammone, AI Strategy, Warren, NJ; Richard Mammone, Rutgers University, New Brunswick, NJ; and Ana Lilia López Aldrete and Aarón Patricio Gaxiola Mascareño, Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado Hospital Regional Valentin Gomez Farias, Jalisco, Mexico.
Abstract:
Purpose In low- to middle-income countries (LMICs), most breast cancers present as palpable lumps; however, most palpable lumps are benign. We have developed artificial intelligence-based computer-assisted diagnosis (CADx) for an existing low-cost portable ultrasound system to triage which lumps need further evaluation and which are clearly benign. This pilot study was conducted to demonstrate that this approach can be successfully used by minimally trained health care workers in an LMIC country. Patients and Methods We recruited and trained three nonradiologist health care workers to participate in an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant pilot study in Jalisco, Mexico, to determine whether they could use portable ultrasound (GE Vscan Dual Probe) to acquire images of palpable breast lumps of adequate quality for accurate computer analysis. Images from 32 women with 32 breast masses were then analyzed with a triage-CADx system, generating an output of benign or suspicious (biopsy recommended). Triage-CADx outputs were compared with radiologist readings. Results The nonradiologists were able to acquire adequate images. Triage by the CADx software was as accurate as assessment by specialist radiologists, with two (100%) of two cancers considered suspicious and 30 (100%) of 30 benign lesions classified as benign. Conclusion A portable ultrasound system with CADx software can be successfully used by first-level health care workers to triage palpable breast lumps. These results open up the possibility of implementing practical, cost-effective triage of palpable breast lumps, ensuring that scarce resources can be dedicated to suspicious lesions requiring further workup.
More Related Videos
Related Concept Videos
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Operational Amplifiers
Real Number Operations
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.
Operant Conditioning
Reinforcement in operant conditioning can be positive or negative, both of which serve to increase the likelihood of a behavior. Positive...