Related Experiment Video
Updated: Feb 6, 2026

High-Resolution Complexome Profiling by Cryoslicing BN-MS Analysis
Published on: October 15, 2019
Selective, sensitive and comprehensive detection of immune complex antigens by immune complexome analysis with
Nozomi Aibara1, Chihiro Kamohara2, Anil K Chauhan3
1Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan.
Abstract:
Comprehensive identification and profiling of antigens in immune complexes (ICs) in biological fluids, such as serum and cerebrospinal fluid, is useful for developing early diagnostic markers and specific treatments for many diseases. We have developed a method, designated "immune complexome analysis", to comprehensively identify the antigens in ICs. In this method, we first purify ICs from biological fluid by using Protein G- or Protein A-coated beads, then these ICs are subjected to tryptic digestion on the beads and subsequent analysis using nano-liquid chromatography-tandem mass spectrometry (nano-LC-MS/MS). We previously used this method to find specific antigens in circulating ICs (CIC-antigens) in serum for autoimmune diseases, infectious disease and cancers. However, this method detects not only CIC-antigens but also antibodies and proteins bound non-specifically to the beads, which restricts the detection of minor peptides released by the digestion of CIC-antigens whose amounts are generally much less than antibodies and the proteins. To selectively detect CIC-antigens with enhanced sensitivity, in this study we compared three methods (Method A, direct tryptic digestion on the beads; Method B, low-pH elution and tryptic digestion; Method C, papain-digestion, elution, and tryptic digestion) and examined which method selectively elutes CIC-antigens from CICs bound to the beads and selectively detects CIC-antigens using nano-LC-MS/MS. We also compared three types of CIC-capturing beads (Protein G-coated magnetic beads, Protein A-coated magnetic beads and Proceptor™-sepharose beads) to examine if parallel use of these beads aids the comprehensive detection of CIC-antigens in immune complexome analysis. Comparison showed that Method C provided the most selective and sensitive detection of CIC-antigens, without interference by antibodies and proteins non-specifically bound to the beads. In addition, using three types of beads allowed the examination of a wide range of CIC-antigens in immune complexome analysis. Therefore, combining Method C with three types of beads should allow the selective and sensitive identification of IC-antigens present in biological fluids from patients with a variety of diseases. The identification of IC-antigens may lead to the development of diagnostic methods and protocols for specific treatments for these diseases.
More Related Videos
07:46Author Spotlight: Advancing Reproductive Immunology with a Protocol for the Quantitative Evaluation of Endometrial Immune Cells
Published on: October 13, 2023
06:03Author Spotlight: Advancing Immune Monitoring in Critical Care Patients Using Whole Blood Assays
Published on: September 20, 2024
Related Concept Videos
Humoral Immune Responses
Antigens Involved in Adaptive Immunity
Complete Antigens
Complete antigens possess both immunogenicity and...
What is the Immune System?
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Introduction to Lymphatic and Immune System
The immune responses can be categorized into two types: innate and adaptive. Innate immunity comprises nonspecific defenses we are...
Functions of the Lymphatic and Immune System
The primary lymphoid organs, including the bone marrow and the thymus, serve as the maturation sites for lymphocytes. Secondary lymphoid organs, like the mucosa-associated lymphoid tissue, activate these lymphocytes and serve as...