Detection of EGFR T790M in a Large Amount of Malignant Ascites Cellblock

Kota Ishioka1, Shinji Sasada, Keiko Ohgino

  • 1Dept. of Respiratory Medicine,Tokyo Saiseikai Central Hospital.

Insights

Detecting EGFR exon 20 T790M mutation in ascitic fluid enabled effective treatment with osimertinib for lung cancer progression. This case highlights fluid analysis as a key diagnostic tool for targeted therapy.

Area of Science:

  • Oncology
  • Molecular Diagnostics
  • Genetics

Background:

  • Lung adenocarcinoma treatment often involves epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKIs).
  • Acquired resistance to first- and second-generation EGFR TKIs commonly arises from the EGFR T790M mutation.
  • Standard diagnostic methods for resistance mutations include repeat tissue biopsy.

Observation:

  • A patient with EGFR exon 19 deletion-mutated lung adenocarcinoma developed malignant ascites and pleural effusion during erlotinib and afatinib treatment.
  • Initial examinations of pleural and ascitic fluids failed to detect the EGFR T790M mutation.
  • Subsequent analysis of a larger volume of ascitic fluid via cellblock successfully identified the EGFR exon 20 T790M mutation.

Findings:

  • The presence of the EGFR exon 20 T790M mutation in ascitic fluid was confirmed.
  • Treatment with osimertinib, an EGFR TKI targeting the T790M mutation, led to significant reduction in ascites and primary tumor burden.
  • Osimertinib demonstrated high efficacy in managing lung cancer progression driven by the T790M mutation.

Implications:

  • Ascitic fluid examination can serve as a viable alternative to tissue biopsy for detecting EGFR T790M mutations in lung cancer.
  • This approach facilitates timely diagnosis and initiation of appropriate targeted therapy, such as with osimertinib.
  • Liquid biopsy in malignant effusions offers a minimally invasive strategy for guiding treatment decisions in advanced lung adenocarcinoma.

Related Concept Videos

Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
7.0K
Detection of Black Holes01:10

Detection of Black Holes

Although black holes were theoretically postulated in the 1920s, they remained outside the domain of observational astronomy until the 1970s.
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
2.6K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.4K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
667
Types of Errors: Detection and Minimization01:12

Types of Errors: Detection and Minimization

Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
11.4K
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.0K