Semiautomatic neck curve reconstruction for intracranial aneurysm rupture risk assessment based on morphological
Sylvia Saalfeld1,2, Philipp Berg3,4, Annika Niemann5
1Department of Simulation and Graphics, Otto-von-Guericke University of Magdeburg, Magdeburg, Germany. sylvia.saalfeld@ovgu.de.
Purpose:
Morphological parameters of intracranial aneurysms (IAs) are well established for rupture risk assessment. However, a manual measurement is error-prone, not reproducible and cumbersome. For an automatic extraction of morphological parameters, a 3D neck curve reconstruction approach to delineate the aneurysm from the parent vessel is required.
Methods:
We present a 3D semiautomatic aneurysm neck curve reconstruction for the automatic extraction of morphological parameters which was developed and evaluated with an experienced neuroradiologist. We calculate common parameters from the literature and include two novel angle-based parameters: the characteristic dome point angle and the angle difference of base points.
Results:
We applied our method to 100 IAs acquired with rotational angiography in clinical routine. For validation, we compared our approach to manual segmentations yielding highly significant correlations. We analyzed 95 of these datasets regarding rupture state. Statistically significant differences were found in ruptured and unruptured groups for maximum diameter, maximum height, aspect ratio and the characteristic dome point angle. These parameters were also found to statistically significantly correlate with each other.
Conclusions:
The new 3D neck curve reconstruction provides robust results for all datasets. The reproducibility depends on the vessel tree centerline and the user input for the initial dome point and parameters characterizing the aneurysm neck region. The characteristic dome point angle as a new metric regarding rupture risk assessment can be extracted. It requires less computational effort than the complete neck curve reconstruction.
Related Concept Videos
Acid-Base Titration Curves
For a titration carried out for 25.00 mL of...
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Relative Risk
Aneurysm I: Introduction
Muscles of the Anterior Neck
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...