Related Experiment Video
Updated: Feb 6, 2026

07:55
High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
Published on: September 22, 2017
10.7K
The Research of Flatfielding Correction Method for Spatial Heterodyne Spectrometer at Systematic Level
Guang Pu Xue Yu Guang Pu Fen Xi = Guang Pu
|August 31, 2018
Summary
A new systematic flatfielding method corrects spatial heterodyne spectrometer response non-uniformity. This advanced technique significantly improves spectral accuracy, crucial for subsequent data processing.
Area of Science:
- Spectroscopy
- Optical Engineering
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Systematic Sampling Method
13.3K
Sampling is a technique to select a portion (or subset) of the larger population and study that portion (the sample) to gain information about the population. Data are the result of sampling from a population. The sampling method ensures that samples are drawn without bias and accurately represent the population. Because measuring the entire population in a study is not practical, researchers use samples to represent the population of interest.
Systematic sampling is one of the simplest methods...
Systematic sampling is one of the simplest methods...
13.3K
IR Spectrometers
2.6K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
2.6K
Introduction and Methods of Leveling
519
Leveling is a surveying procedure used to determine elevation differences between distant points. Elevation refers to the vertical distance above or below a reference datum, typically mean sea level (MSL). In the United States, elevations are often referenced to the mean sea level station at Father Point Rimouski along the St. Lawrence Seaway. To make the datum accessible, permanent markers are established throughout the region. These markers, called benchmarks, have known elevations. If the...
519
Distance Corrections
293
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
293
Mass Spectrometers
9.0K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
9.0K

