Related Experiment Video
Updated: Feb 5, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Reducing variability in apparent operative inclination during total hip arthroplasty: findings of a randomised
Christopher K J O'Neill1, Janet C Hill1, Christopher C Patterson2
11 Primary Joint Unit, Musgrave Park Hospital, Belfast - UK.
Aims:
To determine which of 3 methods of cup insertion most accurately achieved a target apparent operative inclination (AOI) of 35° ± 2.5°: (1) Freehand; (2) Modified Mechanical Alignment Guide (MAG); or (3) Digital Inclinometer assisted.
Methods:
Using a cementless cup via a posterior approach in lateral decubitus 270 participants were recruited, with 90 randomised to each method. The primary outcome was the unsigned deviation from target AOI. The digital inclinometer was used to measure AOI in all cases, though the surgeon remained blinded to the reading intraoperatively for both the Freehand and MAG methods.
Results:
Mean deviation from target AOI for the Freehand, Modified 35° MAG and Digital Inclinometer techniques was 2.9°, 1.8° and 1.3° respectively. When comparing mean deviation from target AOI, statistically significant differences between the Freehand / Inclinometer groups ( p < 0.001), the Freehand / Modified 35° MAG groups ( p < 0.001) and the Digital Inclinometer / Modified 35° MAG groups ( p < 0.023) were evident. The Digital Inclinometer technique enabled the surgeon to achieve a target AOI of 35° ± 2.5° in 88% of cases, compared to 71% of Modified 35° MAG cases and only 51% of Freehand cases.
Discussion:
The Digital Inclinometer and the Modified 35° MAG techniques were both more accurate than the Freehand technique, with the Digital Inclinometer technique proving most accurate overall. Radiographic inclination (RI) is also influenced by operative anteversion; however, the greatest source of error with respect to RI occurs when the pelvic sagittal plane is not horizontal at the time of acetabular component insertion. Clinical Trial Protocol number: NCT01831401.
Related Concept Videos
Inclination of a Line
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....
Moments of Inertia for an Area about Inclined Axes
Clinical Trials: Overview