Related Experiment Video
Updated: Feb 5, 2026

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Using laboratory data to categorise CD4 laboratory turn-around-time performance across a national programme
Lindi-Marie Coetzee1,2, Naseem Cassim1,2, Deborah K Glencross1,2
1National Health Laboratory Service, National Priority Programme, Johannesburg, South Africa.
This study shows how to use median, 75th percentile, and percentage within target CD4 testing data to categorize laboratory performance. This method helps identify underperforming labs for targeted interventions.
Area of Science:
- Clinical diagnostics
- Laboratory medicine
- Public health surveillance
Background:
- The National Health Laboratory Service (NHLS) aims for a 48-hour turnaround time (TAT) for CD4 testing.
- Mean TAT is insufficient for identifying specific laboratory inefficiencies or predicting target achievement.
- Accurate performance metrics are crucial for optimizing HIV patient care.
Purpose of the Study:
- To evaluate the utility of median, 75th percentile, and percentage within target CD4 laboratory TAT data.
- To develop a method for categorizing laboratory performance based on TAT metrics.
- To identify laboratories requiring intervention for improved service delivery.
Main Methods:
- Retrospective analysis of CD4 laboratory TAT data from the 2015-2016 fiscal year.
- Assessment of TAT distribution and the percentage of samples meeting the 48-hour target.
- Utilized a scatter plot to categorize laboratories into performance quadrants based on percentage within target and 75th percentile TAT.
Main Results:
- CD4 TAT data exhibited a positive skew, with a median of 17 hours and a 75th percentile of 25 hours.
- Overall, 93.2% of CD4 samples met the <48 hour TAT target.
- Out of 52 laboratories, 48 demonstrated good performance ( >85% within target and ≤48h 75th percentile), 2 were satisfactory, and 2 were poor performers.
Conclusions:
- Laboratory TAT data can be effectively used to categorize performance.
- A quadrant-based approach for TAT analysis can pinpoint laboratories needing intervention.
- This methodology supports targeted root cause analysis and service improvement initiatives.
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Performing a Simple Data Analysis using MS-Excel Function
SUM: This function calculates the total sum of a range of values. It's the foundation for aggregating data, essential for determining overall trends and totals in datasets.
AVERAGE: It computes the mean value of a given set of numbers, providing a quick insight into the central...
National Nursing Organizations I
National Nursing Organizations II
The AACN emphasizes a healthy work environment through six standards to achieve an optimal patient outcome. The standards are appropriate staffing, meaningful recognition, collaboration, authentic leadership, effective communication, and decision-making. In addition, AACN provides certification programs, webinars, journals, and...
How Data are Classified: Categorical Data
Data are classified based on whether they are measurable or not. Categorical data cannot be measured; instead, it can be divided into categories. For example, if Y denotes a person's party affiliation, some examples of Y include...
How Data are Classified: Numerical Data
Quantitative data may be either discrete or continuous. All quantitative data that take on only specific numerical...