Evaluation of rapid KPC carbapenemase detection method based on MALDI-TOF VITEK MS spectra analysis

Anna Rita Centonze1, Anna Bertoncelli1, Chiara Savio2

  • 11​Department of Diagnostics and Public Health, Verona University, Verona, Italy.

Related Concept Videos

MALDI-TOF Mass Spectrometry01:19

MALDI-TOF Mass Spectrometry

Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
6.9K
Emission Spectra02:39

Emission Spectra

When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
76.4K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
667
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
6.0K
Matrix-Assisted Laser Desorption Ionization (MALDI)01:08

Matrix-Assisted Laser Desorption Ionization (MALDI)

Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
1.2K
Classification of Titrimetric Analysis Based on Reaction Types01:01

Classification of Titrimetric Analysis Based on Reaction Types

Titrimetric analysis in solution chemistry involves measuring the volume of solutions and is often called volumetric analysis. The standard solution of known concentration in the burette is called the titrant, whereas the solution of unknown concentration in the flask is called the analyte, or titrand. Titrimetric analyses can be classified into four types based on the reactions between the titrant and analyte.
Titrations between an acid and a base lead to neutralization reactions that form...
1.8K