Evaluation of rapid KPC carbapenemase detection method based on MALDI-TOF VITEK MS spectra analysis
Anna Rita Centonze1, Anna Bertoncelli1, Chiara Savio2
11Department of Diagnostics and Public Health, Verona University, Verona, Italy.
Abstract:
Clinical microbiology laboratories in hospital settings need to be able to identify patients who carry carbapenemase-producing bacterial strains quickly in order to contain their spread and initiate proper pharmacological therapy. The aim of this study was to confirm the correlation between KPC production and a characteristic mass spectrometry (MS) peak (11 109 Da±8) to validate the use of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS as a rapid screening tool. With this aim, 176 selected clinical samples that were KPC-producing and 260 control samples that were carbapenem-susceptible or carbapenem-resistant through other resistance mechanisms, or were producing hydrolytic enzymes other than KPC, were analysed. The presence of the 11 109 Da peak in the spectra of 99.4 % (175/176) of the KPC-producing strains compared to the controls, which all lacked the peak, confirmed a strong correlation between KPC production and the presence of the 11 109 Da peak in the MALDI-TOF MS spectrum. The high sensitivity (98.7 %) and specificity (100 %) of the peak searching in the MALDI-TOF MS spectra mean that 11 109 Da peak searching is a suitable screening tool in KPC-endemic regions.
More Related Videos
11:25Whole-cell MALDI-TOF Mass Spectrometry is an Accurate and Rapid Method to Analyze Different Modes of Macrophage Activation
Published on: December 26, 2013
13:29Rapid Identification of Gram Negative Bacteria from Blood Culture Broth Using MALDI-TOF Mass Spectrometry
Published on: May 28, 2014
Related Concept Videos
MALDI-TOF Mass Spectrometry
Emission Spectra
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Matrix-Assisted Laser Desorption Ionization (MALDI)
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...