Related Experiment Video
Updated: Feb 5, 2026

The Measurement and Treatment of Suppression in Amblyopia
Published on: December 14, 2012
Effect of amblyopia treatment on choroidal thickness in hypermetropic anisometropic amblyopia using swept-source
Syunsuke Araki1, Atsushi Miki2,3, Katsutoshi Goto1
1Department of Ophthalmology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama, 701-0192, Japan.
Background:
Recent studies using optical coherence tomography (OCT) have indicated that choroidal thickness (CT) in the anisometropic amblyopic eye is thicker than that of the fellow and normal control eyes. However, it has not yet been established as to how amblyopia affects the choroid thickening. The purpose of the present study was to investigate the effect of amblyopia treatment on macular CT in eyes with anisometropic amblyopia using swept-source OCT.
Methods:
Thirteen patients (mean age: 6.2 ± 2.4 years) with hypermetropic anisometropic amblyopia were included in this study. Visual acuity (VA), axial length (AL), and CT were measured at the enrollment visit and at the final visit, after at least 6 months of treatment. CT measurements were corrected for magnification error and were automatically analyzed using built-in software and divided into three macular regions (subfoveal choroidal thickness (SFCT), center 1 mm, and center 6 mm). A one-way analysis of covariance using AL as a covariate was performed to determine whether CT in amblyopic eyes changed after amblyopia treatment.
Results:
The average observation period was 22.2 ± 11.0 months. After treatment, VA (logMAR) improvement in the amblyopic eyes was 0.41 ± 0.19 (p < 0.001). SFCT, center 1 mm CT, and center 6 mm CT were significantly thicker in the amblyopic eyes compared with the fellow eyes both before and after treatment (p < 0.05 for all comparisons). There were no significant changes in SFCT, center 1 mm CT, or center 6 mm CT before and after treatment in the amblyopic (p = 0.25, 0.21, and 0.84, respectively) and fellow (p = 0.75, 0.84, and 0.91, respectively) eyes. The correlation between changes in logMAR versus changes in CT after treatment was not significant.
Conclusions:
Although VA in amblyopic eyes was significantly improved after treatment, the choroid thickening of anisometropic amblyopic eyes persisted, and there was no significant change found in the CT after the treatment. Our findings suggest that thickening of the CT in amblyopia is not directly related to visual dysfunction.
More Related Videos
03:47Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
Related Concept Videos
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
AC Sources
Sources of Law
Constitutional law is foundational, deriving from federal and state constitutions, and...
Source Transformation
It is essential to note that when...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...