Related Experiment Video
Updated: Feb 5, 2026

Modeling the Effects of Hemodynamic Stress on Circulating Tumor Cells using a Syringe and Needle
Published on: April 27, 2021
Feasibility of needle and syringe programs in Tajikistan distributing low dead space needles
William A Zule1, Alisher Latypov2, David Otiashvili3
1RTI International, 3040 E. Cornwallis Road, PO Box 12194, Research Triangle Park, NC, 2709-2194, USA. zule@rti.org.
Background:
In 2012, the World Health Organization recommended that needle and syringe programs offer their clients low dead space insulin syringes with permanently attached needles. However, in many countries, these syringes are not acceptable to a majority of people who inject drugs. This study assessed the feasibility of working with needle and syringe programs to implement the WHO recommendation using low dead space detachable needles. The study also assessed the acceptability of the needles.
Methods:
Two needle and syringe programs in Tajikistan-one in Kulob and one in Khudjand-received 25,000 low dead space detachable needles each. The programs distributed low dead space detachable needles and a marketing flyer that emphasized the relative advantages of the needles. Each program also enrolled 100 participants, and each participant completed a baseline interview and a 2-month follow-up interview.
Results:
At follow-up, 100% of participants reported trying the low dead space detachable needles, and 96% reported that they liked using the needles. Both needle and syringe programs distributed all their needles within the first 60 days of the project indicating use of the needles, even among clients who did not participate in the study.
Conclusions:
This project demonstrates that it is feasible for needle and syringe programs to offer and promote low dead space needles to their clients. The findings indicate that low dead space needles are acceptable to needle and syringe program clients in these Tajikistan cities. To reduce HIV and hepatitis C virus transmission, needle and syringe programs should offer low dead space needles, low dead space insulin syringes in addition to standard needles, and syringes to their clients.
Related Concept Videos
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
State Space Representation
Consider an RLC circuit, a...
Space Trusses: Problem Solving
Consider a tripod consisting of a tetrahedral space truss with a ball-and-socket joint at C. Suppose the height and lengths of the horizontal and vertical...
Transfer Function to State Space
In an RLC...
State Space to Transfer Function
The transformation process begins with the state-space representation, characterized by the state equation and the output equation. These equations are typically represented as:
Rocket Propulsion in Empty Space - I

