Related Experiment Video
Updated: Feb 5, 2026

A Protocol for Constructing a Rat Wound Model of Type 1 Diabetes
Published on: February 17, 2023
Use of flash glucose-sensing technology (FreeStyle Libre) in youth with type 1 diabetes: AWeSoMe study group
Zohar Landau1,2, Shirli Abiri3,4, Noah Gruber4,5
1Pediatric Endocrine and Diabetes Unit, E. Wolfson Medical Center, Holon, Israel. landau.zohar@gmail.com.
Aims:
Frequent glucose testing is required for optimal management of type 1 diabetes (T1D). Limited data are available regarding real-world experience of the novel technology for monitoring by continuous interstitial fluid glucose (IFG), using flash glucose-sensing technology (FSL-CGM). We aimed to assess the effect of FSL-CGM in a real-life clinical setting on glycemic control parameters, compliance, and adverse events among pediatric and young adult T1D patients.
Methods:
This observational multi-center study assessed FSL-CGM use (6-12 months) in T1D patients (mean ± SD age 13.4 ± 4.9 years) who purchased the device out-of-pocket. Outcome measures included HbA1c, mean IFG levels, CGM metrics [time in hypoglycemia (< 54 mg/dL; < 3 mmol/L), in target range (70-180 mg/dL; 3.9-10 mmol/L), and in hyperglycemia > 240 mg/dL; > 13.3 mmol/L)], frequency of self-monitoring of blood glucose, acute complications, skin reactions, and reasons for initiation/discontinuation.
Results:
Among patients with regular use of the FSL-CGM (n = 59), mean HbA1c decreased from 8.86 ± 0.23 to 8.05 ± 0.2% (73.3-64.5 mmol/mol) in 3 months (p = 0.0001) and plateaued thereafter. A clinically significant reduction in HbA1c (defined as a decrease of ≥ 0.5%) was associated with shorter diabetes duration. Of 71 patients who initiated use of the FSL-CGM, 12 (16.9%) discontinued during the study period. No statistically significant changes were found after FSL-CGM use, in mean and standard deviation IFG levels, and in time of glucose levels in target, hypoglycemia, and hyperglycemia ranges. One patient with hypoglycemia unawareness was found dead-in-bed while using FSL-CGM.
Conclusions:
Real-life observational data in a self-selected young T1D population demonstrated a significant and sustained reduction in HbA1c with FSL-CGM in one-third of the participants. Surveillance of glucose monitoring should be individualized, especially for patients with hypoglycemia unawareness.
Related Concept Videos
Naturalistic Observations
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...
Half-life of a Reaction
Diabetes Mellitus: Type 2 and Gestational
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
The Sense of Self: Reflected Self-Appraisal and Social Comparison