Related Experiment Video
Updated: Feb 5, 2026

Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
Disinfection efficacy of ultraviolet germicidal irradiation on airborne bacteria in ventilation ducts
Yi Yang1,2, Huihui Zhang3, Sunday Segbenu Nunayon3
1School of Mechanical and Power Engineering, Guangdong Ocean University, Zhanjiang, China.
Abstract:
A full-scale ventilation duct ultraviolet germicidal irradiation (in-duct UVGI) system was designed to investigate its disinfection efficacy on five airborne pathogens: Serratia marcescens, Pseudomonas alcaligenes, Escherichia coli, Salmonella enterica, and Staphylococcus epidermidis, with airflow Reynolds numbers from 4 × 104 to 8 × 104 . By varying the UV intensity, the susceptibility constants (Z-values) of the bacteria were experimentally determined to be 1.2, 1.0, 0.60, 0.39, and 0.37 m2 /J for S. marcescens, P. alcaligenes, E. coli, S. enterica, and S. epidermidis, respectively. The disinfection efficacy was numerically investigated on the basis of the predicted irradiance, which included emissive irradiance and diffuse refection irradiance. The results suggest that it is vital to properly evaluate the UV dose (irradiance intensity) received by airborne bacteria to determine their Z-values. In-duct UVGI inactivated nearly all of the test bacteria with Reynolds numbers of 4 × 104 (inlet velocity = 3 m/s), and the disinfection efficacy decreased as Reynolds numbers increased. The in-duct UVGI system would potentially provide a supplementary solution for improving indoor air quality (IAQ) within mechanical ventilated/air-conditioned environment.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Self-Efficacy
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...