Related Experiment Video
Updated: Feb 5, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Total-body irradiation using linac-based volumetric modulated arc therapy: Its clinical accuracy, feasibility and
Bora Tas1, Ismail Faruk Durmus1, Ayse Okumus1
1Department of Radiation Oncology, Yeni Yuzyil University Gaziosmanpasa Hospital, Istanbul, Turkey.
Purpose:
To report the feasibility, accuracy, and reliability of volumetric modulated arc therapy (VMAT)-based total-body irradiation (TBI) treatment in patients with acute myeloid leukemia (AML) or acute lymphoblastic leukemia (ALL).
Materials And Methods:
From 2015 to 2018, 30 patients with AML or ALL were planned and treated with VMAT-based TBI, which consisted of three isocenters and three overlapping arcs. TBI dose was prescribed to 90% of the planning treatment volume (PTV) receiving 12 Gy in six fractions, at two fractions per day. Mean lung and kidney doses were restricted less than 10 Gy, and maximum lens dose less than 6 Gy. Quality assurance (QA) comprised the verification of the irradiation plans via dose-volume histogram (DVH) based 3D patient QA system.
Results:
Average mean lung dose was 9.7 ± 0.2 Gy, mean kidney dose 9.6 ± 0.2 Gy, maximum lens dose 4.5 ± 0.4 Gy, mean PTV dose 12.7 ± 0.1 Gy, and heterogeneity index of PTV was 1.16 ± 0.02 in all patients. Grade 3 or more acute radiation toxicity was not observed. When comparing plan and DVH-based 3D patient QA results, average differences of 3.3% ± 1.3 in mean kidney doses, 1.1% ± 0.7 in mean lung doses, and 0.9% ± 0.4 in mean target doses were observed.
Conclusion:
Linac-based VMAT increased the dose homogeneity of TBI treatment more than extended SSD techniques. Partial cone-beam CT and optical surface-guided system assure patient positioning. DVH-based 3D patient dose verification QA was possible with linac-based VMAT showing small differences between planned and delivered doses. It is feasible, accurate, and reliable.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Reliability and Validity
Arc Length of a Curve
Arc Length Function
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Arc Length of a Curve: Problem Solving