Published on: September 2, 2009
Development of a new radial passive sampling device for atmospheric NOx determination
Oriana Motta1, Raffaele Cucciniello2, Rosa La Femina2
1Dipartimento di Medicina Chirurgia e Odontoiatria "Scuola Medica Salernitana", Università degli Studi di Salerno, via Salvatore Allende, 84081 Baronissi, SA, Italy.
Abstract:
In this paper we used Na2CO3-impregnated silica as reactive substrate for the determination of atmospheric NOx (NO+NO2) by using a passive sampling device, with radial symmetry, which is unprecedented. We conducted laboratory and field tests at an urban setting, with co-located passive samplers and continuous measurements of NOx by a chemiluminescence detector, used as reference. The performance of the carbonate-based sorbent for the NOx sampler was evaluated in two different time frames (autumn 2016 and winter 2017), characterised by different environmental conditions. The comparison of the NOx concentration levels measured by passive sampling, using Na2CO3 as NOx sorbent, showed a close relationship with those obtained by the chemiluminescence analyzer. Validation experiments in the laboratory and in the field are reported together with the calculation of the diffusion-sampling rate of the samplers.
More Related Videos
11:47The Effect of Interfacial Chemical Bonding in TiO2-SiO2 Composites on Their Photocatalytic NOx Abatement Performance
Published on: July 4, 2017
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...