Tc-HDP quantitative SPECT/CT in transthyretin cardiac amyloid and the development of a reference interval for
Stuart C Ramsay1,2, Karen Lindsay1, William Fong1
11Department of Nuclear Medicine and Specialised PET Service, Ned Hanlon Building, Royal Brisbane and Women's Hospital (RBWH), Herston, QLD 4029 Australia.
Background:
99mTechnetium-HDP (HDP) bone scans differentiate transthyretin (ATTR) cardiac amyloid from other infiltrative myocardial diseases. These scans are not quantitative and are assessed by comparing myocardial uptake to bone. This study examined whether quantitative HDP SPECT/CT can discriminate individuals with cardiac ATTR from the population without this disease.
Methods:
HDP thoracic xSPECT/CT QUANT (xQUANT) was performed in 29 patients: ATTR cardiac amyloid (n = 6); AL cardiac amyloid (n = 1); other infiltrative myocardial disease (n = 4); no known infiltrative cardiac disease (n = 18). SUVmax measured within volumes of interest for whole heart, ascending aorta blood pool, and specific bones. HDP myocardial uptake calculated as whole heart minus blood pool.
Results:
The cardiac ATTR group had greater HDP myocardial uptake than those with no known infiltrative disease (p = 0.002). AL and other myocardial diseases had uptake indistinguishable from the group with no known infiltrative cardiac disease. The SUVmaxima were sufficiently similar between individuals without cardiac ATTR that a 99% reference interval for HDP uptake could be calculated, providing an upper limit cut point of SUVmax 1.2. Individuals with cardiac ATTR had SUVmax well above this cut point.
Conclusion:
Quantitative SPECT/CT can measure HDP myocardial uptake in individuals with normal hearts and those with cardiac ATTR without recourse to comparison with bone. It enables calculation of a reference interval for HDP myocardial uptake in the population without ATTR cardiac amyloid. Using this reference interval single individuals with cardiac ATTR can be accurately discriminated from the non-affected population. This technique uses a NIST traceable calibration source, potentially allowing development of multicentre clinical decision limits. Its role in disease management warrants further assessment.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Confidence Interval for Estimating Population Mean
A confidence interval for the mean is a range of values that provides an estimate of the population mean. As the...
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Population Growth
What is Population Genetics?
Conservation of Small Populations