Related Experiment Video
Updated: Feb 5, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Variability of carboplatin dose calculation methods in Spain
Cristina Cuesta-Grueso1, Amparo Burgos-San José2, Gerardo Cajaraville-Ordoñana3
11 Pharmacy Department, Hospital of Denia Marina Salud, Alicante, Spain.
Objective:
To describe and analyze the variability in carboplatin dosing strategies in Spanish hospitals.
Methods:
We designed a questionnaire consisting of 19 multiple-choice items structured in two sections (hospital characteristics and carboplatin dosing data). The questionnaire was sent by e-mail to all the oncology pharmacists included in the register of the Spanish Oncology Pharmacy Group (GEDEFO), and we analyzed the completed questionnaires.
Results:
Response rate was 33.5% from a total of 185 pharmacy services invited to take part in the survey. All hospitals used the Calvert formula to calculate carboplatin dose with glomerular filtration rate estimated by a formula, most commonly the Cockcroft-Gault equation (80.7%). Carboplatin doses were capped in most hospitals (91.9%): 54.8% capped creatinine clearance at 125 mL/min, 11.3% capped serum creatinine, and 19.3% capped both creatinine clearance and serum creatinine. Serum creatinine cut-off values ranged from 0.36 mg/dL to 1 mg/dL. The most commonly used body weight was actual body weight for underweight, normal weight, and overweight patients. The use of adjusted ideal body weight increased in obese and especially in morbidly obese patients.
Conclusion:
The results from this survey show the variability that exists in carboplatin dose calculation methods among Spanish hospitals and the need to continue investigating to find the optimum dose calculation method and unify criteria to avoid differences between sites that can affect effectiveness and toxicity of carboplatin-containing treatments.
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Calculating Standard Free Energy Changes
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
Calculating pH Changes in a Buffer Solution
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...

