Related Experiment Video
Updated: Feb 5, 2026

Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer
Published on: September 28, 2015
Non-invasive measurement of lubricating oil viscosity using an ultrasonic continuously repeated chirp shear wave
O F Manfredi1, R S Mills1, M M Schirru1
1Leonardo Centre for Tribology, University of Sheffield, Sheffield S1 3JD, UK.
Abstract:
The ability to monitor the viscosity of lubricating oils within metallic products is of interest to many industries, these being the automotive, aerospace and food industries to name a few. Acoustic mismatch at the metallic-liquid interface restricts ultrasonic signal transmission and so limits applicability and sensitivity of the technique. In this work, we propose the use of a continuously repeated chirp (CRC) shear wave to amplify the measurable acoustic response to liquid viscosity. The technique enables multiple reflections to superimpose inside the component and form a quasi-static standing wave whose amplitude spectrum depends on the condition at the solid-liquid boundary. Bare element shear ultrasonic transducers of 5 MHz resonant frequency were bonded to the lower surface of an aluminium plate in a pitch-catch arrangement to measure liquid in contact with the upper surface. Transducers were pulsed using a continuously repeated frequency sweep, from 0.5 to 9.5 MHz over 10 ms. The amplitude spectrum of the resulting standing wave was observed for a series of standard viscosity oils, which served as a calibration procedure, from which the standing wave reflection coefficient (S), was obtained. Measurements of 17 blended oils ranging in viscosity from 1080 to 6.7 mPa s were made. The technique was also evaluated with the addition of a polyimide matching layer (ML) between the metallic and liquid interface. Ultrasonic viscosity measurement values were then compared to measurements made using a conventional laboratory viscometer. The CRC method was found to significantly improve the sensitivity of viscosity measurement at a metal-liquid interface when compared to a single frequency burst with the benefit of low cost signal generation and acquisition hardware requirements. The CRC method is also capable of instant rapid response measurements as the signal responds in real time without the need to wait for a returning pulse.
Related Concept Videos
Viscosity
The SI unit of viscosity is...
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Viscosity of Fluid
The Wave Nature of Light
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.

