Related Experiment Video
Updated: Feb 5, 2026

Mouse Model of Pressure Ulcers After Spinal Cord Injury
Published on: March 9, 2019
High Voltage Monophasic Pulsed Current (HVMPC) for stage II-IV pressure ulcer healing. A systematic review and
Beshoy Girgis1, José Alberto Duarte1
1CIAFEL, Faculty of Sports, University of Porto, Portugal.
Abstract:
This review was conducted to determine and quantify the efficacy of high-voltage monophasic pulsed current (HVMPC) in the treatment of stage II-IV pressure ulcers (PrUs), identify the details of HVMPC intervention parameters and the superior protocol, and ascertain other potential benefits and the safety of HVMPC intervention. Eleven studies, nine randomized controlled trials (RCTs) and two case series studies, matched the criteria and were included in the systematic review, whereas, only level 1 evidence RCTs were included in the meta-analysis. The percentage of wound surface area reduction per week was 12.39%; 95% CI, [10.43-14.37] for HVMPC plus standard wound care (SWC) and 6.96%; 95% CI, [5.56-8.38] for SWC alone or SWC plus sham HVMPC. The net effect of HVMPC was 5.4% per week (an increase of 78% greater than SWC alone or SWC plus sham HVMPC). Level 1, 2 and 4 evidence studies have consistently indicated that HVMPC plus SWC were more effective than SWC alone or SWC plus sham HVMPC in treating stage II-IV PrUs. Level 1 evidence studies showed that HVMPC intervention improved the healing of PrUs (reduced wound surface area), and combined with SWC, increased the probability of complete healing and almost eliminated the probability of worsening of healing. HVMPC intervention was shown to be relatively safe, with rare adverse reactions.
More Related Videos
Related Concept Videos
Peptic Ulcer Disease IV: Management
The therapeutic approach involves ensuring adequate rest, implementing drug therapy, promoting smoking cessation, making dietary modifications, and emphasizing long-term follow-up care.
Pharmacological management
The prevailing therapy for peptic ulcers involves a combination of managing the patient's current...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Pulse
The pulse serves as a clinical...

