Related Experiment Video
Updated: Feb 5, 2026

Mechanisms Underlying Gut Hormone Secretion Using the Isolated Perfused Rat Small Intestine
Published on: February 26, 2019
Silver-Coated Endotracheal Tubes Cleaned With a Mechanism for Secretion Removal
Massimiliano Pirrone1,2, David Ae Imber1, Francesco Marrazzo1
1Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts.
Background:
Biofilm on the surface of endotracheal tubes (ETTs) is associated with ventilator-associated pneumonia. The use of silver-coated ETTs has been suggested to reduce the occurrence of ventilator-associated pneumonia by preventing biofilm formation. However, mucus accumulation can reduce the antibacterial activity of silver-coated ETTs by isolating bacterial colonies from the silver surface. We hypothesized that, in mechanically ventilated subjects, periodic removal of secretions through the use of a cleaning device would enhance the antimicrobial properties of silver-coated ETTs and thus reduce bacterial colonization.
Methods:
Subjects were randomized to either standard suctioning (blind tracheal suctioning, control group) or blind tracheal suctioning plus cleaning maneuver every 8 h (treatment group). Tracheal aspirates were collected immediately before extubation for microbiological culture. After extubation, ETTs were collected for both cultural and non-cultural microbiological analysis and biofilm isolation.
Results:
39 subjects expected to be ventilated for > 48 h were enrolled; 36 ETTs (18 control, 18 treatment) and 29 tracheal samples (15 control, 14 treatment) were collected. Among the ETTs positive for bacterial colonization (15 vs 9, P = .18), cleaning maneuvers did not reduce microbial load, shown as the decimal logarithm of colony-forming units (CFU) per mL (1.6 ± 1.2 vs 0.9 ± 1.2 logCFU/mL, P = .15). There was a trend toward decreased biofilm deposition (439.5 ± 29.0 vs 288.9 ± 157.7 mg, P = .09) in the treated ETTs. No significant differences were observed in the number of positive tracheal aspirates (13 vs 10, P = .39) or in the microbial load (4.8 ± 4.0 vs 4.2 ± 3.8 logCFU/mL, P = .70) of tracheal secretions. Finally, no differences in the microbial load of Gram-positive organisms, Gram-negative organisms, or yeasts were found between the ETTs and tracheal aspirates of the 2 groups.
Conclusions:
In 39 critically-ill subjects intubated with silver-coated ETTs, periodic cleaning maneuvers did not decrease bacterial colonization of the ETTs and did not lower respiratory tract colonization compared to the standard suctioning. (Clinicaltrials.gov registration NCT02120001.).
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Uterine Tubes
Pinching-off of Coated Vesicles