Impedimetric immunosensor for dengue diagnosis using graphite screen-printed electrodes coated with
Thiago Coimbra Pimenta1, Cátia da Cruz Santos1, Ronaldo Luís Thomasini2
1Laboratório de Eletroquímica e Nanotecnologia Aplicada, Instituto de Ciência e Tecnologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Rodovia MGT 367, Km 583, 5000, Alto da Jacuba, Diamantina-MG, 39100-000, Brazil.
Abstract:
Dengue is an infectious viral disease transmitted by the Aedes aegypti mosquito, the control of which is complex. In addition, the clinical diagnosis is difficult to perform since it resembles other febrile infections; thus, the development of more effective methods to detect dengue virus (DV) has drawn increasing attention. The present study aimed to develop an impedimetric immunosensor for dengue diagnosis using a screen-printed electrode (SPE) functionalized with polymer films derived from 4-aminophenylacetic acid (4-APA). Data obtained from scanning electron microscopy (SEM) showed the deposition of a uniformly distributed material over the electrode surface. The immunosensor was based on the specific interaction between dengue antigen, NS1 protein, and anti-NS1 antibodies, IgG and IgM. In a characterization study using cyclic voltammetry (CV), the polymer film showed two oxidation peaks at +0.17 and + 0.35 V in 0.50 M sulfuric acid solution, indicating its adsorption and electroactivity at the SPE surface. Electrochemical impedance spectroscopy (EIS) measurements showed a higher charge transfer resistance (Rct) to the polymer film-modified SPE as compared with the bare SPE, corroborating a previous study. The best rNS1 concentration for immobilization was 1.00 ng/mL, and the immunoreaction time between the antigen (Ag) and the antibody (Ab) was 20 min. Dilutions of positive and negative clinical serum samples were evaluated by EIE, from which it was possible to elucidate, for the positive serum, that the more diluted the serum the greater the Rct. Negative serum also showed an analytical signal, probably due to the presence of non-specific antibodies; however, the generated signal presented values closer to the rNS1 signal, indicating good selectivity of the proposed platform. The experiments were repeated using bare SPE to verify the importance of the polymer film in biosensor construction. No significant difference was observed between these results. Graphical abstract Proposed schematic for the genosensor development.
More Related Videos
Related Concept Videos
Acid Halides to Alcohols: LiAlH4 Reduction
The mechanism proceeds in three steps. First, the nucleophilic hydride ion attacks the carbonyl carbon of the acid halide to form a tetrahedral intermediate. Next, the carbonyl group is re-formed, and the halide ion departs as a leaving group, generating an aldehyde. A second nucleophilic attack by the hydride yields an alkoxide ion, which, upon protonation, gives a primary alcohol as...
Standard Electrode Potentials
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Pinching-off of Coated Vesicles
Polyprotic Acids
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...