Near Simultaneous Laser Scanning Confocal and Atomic Force Microscopy Conpokal on Live Cells
Published on: August 11, 2020
Scanning diffracted-light microscopy
Scanning diffracted light directions enables Fourier ptychographic microscopy (FPM) with perpendicular illumination. This method also facilitates illumination-direction-multiplexing FPM using ring-shaped illumination, enhancing imaging diversity.
Area of Science:
- Optics and Photonics
- Microscopy Techniques
- Image Processing
Background:
- Fourier ptychographic microscopy (FPM) requires image diversity for high-resolution reconstruction.
- Traditional FPM often relies on varying illumination angles.
- Achieving image diversity with simpler illumination setups is desirable.
Purpose of the Study:
- To demonstrate a novel method for achieving image diversity in FPM.
- To enable FPM implementation using only perpendicular illumination.
- To adapt this method for illumination-direction-multiplexing FPM with ring-shaped illumination.
Main Methods:
- Analyzing the direction of diffracted light from a sample.
- Implementing FPM using perpendicular illumination by scanning diffracted light directions.
- Utilizing a ring-shaped condenser for illumination-direction-multiplexing FPM.
Main Results:
- Successfully achieved image diversity necessary for FPM with perpendicular illumination.
- Demonstrated the feasibility of illumination-direction-multiplexing FPM using the proposed method.
- Showcased the versatility of scanning diffracted light for advanced microscopy.
Conclusions:
- Scanning diffracted light directions is a viable strategy for enhancing FPM capabilities.
- This technique simplifies FPM implementation by reducing illumination complexity.
- The method offers a pathway to advanced imaging with adaptable illumination schemes.
More Related Videos
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
Published on: June 16, 2016
10:00Low-Cost Cryo-Light Microscopy Stage Fabrication for Correlated Light/Electron Microscopy
Published on: June 5, 2011
Related Concept Videos
Interference and Diffraction
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Leaky Scanning
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Light Acquisition
Light as Energy
Photons
A photon is a discrete electromagnetic particle or bundle of energy. Photons are characterized by their frequency, wavelength, and amplitude, similar to the properties of a wave. Waves with higher frequencies transmit more energy and have shorter wavelengths than longer wavelengths that transmit...