Objective:
This study aimed to evaluate the original (OR) and repair (RR) fracture resistance of a semi-interpenetrating polymer network (semi-IPN)-based short fiber-reinforced composite compared to dimethacrylate-based composite materials by means of the V-notch test.
Methods And Materials:
Circular specimens (5×2 mm) with a centrally machined 90° V-shaped notch were prepared. Four bulk fill (Filtek Bulk Fill, Venus Bulk Fill, TetricEvo Ceram Bulk Fill, SDR), three microfilled hybrid (GC-Anterior, GC-Posterior, Z250), one nanofilled (SupremeXTE), and two short fiber-reinforced (Alert, everX Posterior) composites were selected. EverX Posterior was the semi-IPN material. Specimens (n=12/group) were either dry or water stored for 7 and 30 days, respectively, at 37°C and then loaded in two-point load until fracture. One-half of each tested specimen was used for the repair procedure. Repairing surfaces were diamond-bur ground, etched, and treated with silane containing universal adhesive (Scotchbond Universal) before repair.
Results:
Three-way analysis of variance revealed a significant statistical difference between the groups ( p<0.05). The fracture resistance of dry-stored groups was greater than that of water-stored groups. The highest OR was observed for dry-stored Alert (23.4 N/mm), which significantly deteriorated in water (17.4 N/mm) ( p<0.05). The highest RR was observed for everX Posterior (20.0 N/mm), which did not deteriorate in water significantly (19.0 N/mm) ( p>0.05). The everX Posterior preserved the specimens' integrity at the final fracture load (ductile fracture), whereas all other materials fractured into two halves at the interface (adhesive failure).
Conclusions:
The only material that provided enhanced repair strength that was close to the original cohesive strength of the material was everX Posterior. The endurance of repaired restorations can be improved by using semi-IPN-based filling material.
More Related Videos
09:54Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Fiber Reinforced Concrete
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Additives and Fillers in Concrete
The...
Reinforcement
Positive reinforcement occurs when a behavior is followed by the presentation of a rewarding stimulus, increasing the frequency of that behavior. For example:
Mismatch Repair
Long-patch Base Excision Repair