Related Experiment Video
Updated: Feb 5, 2026

Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Does heart rate variability improve prediction of failed extubation in preterm infants?
Marciali Gonçalves Fonseca Silva1, Michele Lima Gregório2, Moacir Fernandes de Godoy2,3
1Department of Pediatrics and Pediatric Surgery Surgery - Sao Jose do Rio Preto Medical School (FAMERP), São José do Rio Preto, SP, Brazil.
Abstract:
Background Prematurity and its respective comorbidities may result in longer periods of mechanical ventilation in intensive care units (ICU). A method for the assessment of organic maturity would be useful for this population. Heart rate variability (HRV), as an indicator of homeostasis, is a well-established tool for this approach. The objective of the study was to assess HRV in intubated preterm infants in ICU immediately prior to extubation and correlate HRV with clinical evaluation outcomes. Methods A total of 46 preterm infants, 13 (28.2%) males, were prospectively studied and divided into a group with failed extubation (FEG: n=11) and a group with successful extubation (SEG: n=35). HRV was evaluated in time, frequency and nonlinear domains with a Polar RS800 device. HRV measurements were assessed with Kubios HRV Premium Software and statistically analyzed with the StatsDirect Statistical Software, version 1.9.2015 (2002). P<0.05 values were considered as statistically significant. Results There were no significant differences between heart rate variables of failed and successful extubation when analyzing the total group. However, the analysis of the sub-group of preterm infants weighing less than 1000 g showed a clear differentiation between the groups, when the nonlinear variables (approximate entropy, sample entropy and multiscale entropy 1, 2 and 3) were used, demonstrating that the group with successful extubation shows greater complexity and, therefore, relatively greater autonomic stability. Conclusion HRV was effective in predicting failed extubation in preterm infants when evaluated in a nonlinear domain and in preterm infants weighing less than 1000 g.
More Related Videos
Related Concept Videos
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Improving Translational Accuracy

