Related Experiment Video
Updated: Feb 5, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Thrombocytopenia After Transcatheter Valve-in-Valve Implantation: Prognostic Marker or Mere Finding?
Renato C de Souza1, Leonardo Paim1, Guilherme Viotto1
1Cardiovascular Surgery Division, Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (InCor-HCFMUSP), São Paulo, SP, Brazil.
Objective:
To analyze the behavior of platelets after transcatheter valve-in-valve implantation for the treatment of degenerated bioprosthesis and how they correlate with adverse events upon follow-up.
Methods:
Retrospective analysis of 28 patients who received a valve-in-valve implant, 5 in aortic, 18 in mitral and 5 in tricuspid positions. Data were compared with 74 patients submitted to conventional redo valvular replacements during the same period, and both groups' platelet curves were analyzed. Statistical analysis was conducted using the IBM SPSS Statistics(r) 20 for Windows.
Results:
All patients in the valve-in-valve group developed thrombocytopenia, 25% presenting mild (<150.000/µL), 54% moderate (<100.000/µL) and 21% severe (<50.000/µL) thrombocytopenia. The platelet nadir was on the 4th postoperative day for aortic ViV, 2nd for mitral and 3rd for tricuspid patients, with the majority of patients recovering regular platelet count. However, the aortic subgroup comparison between valve-in-valve and conventional surgery showed a statistically significant difference from the 7th day onwards, where valve-in-valve patients had more severe and longer lasting thrombocytopenia. This, however, did not translate into a higher postoperative risk. In our study population, postoperative thrombocytopenia did not correlate with greater occurrence of adverse outcomes and only normal preoperative platelet count could significantly predict a postoperative drop >50%.
Conclusion:
Although thrombocytopenia is an extremely common finding after valve-in-valve procedures, the degree of platelet count drop did not correlate with greater incidence of postoperative adverse outcomes in our study population.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Finding the Center of Gravity
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...