Uncertainty analysis of axial temperature and Seebeck coefficient measurements
Sajad Yazdani1, Hyun-Young Kim1, Michael Thompson Pettes1
1Department of Mechanical Engineering, University of Connecticut, Storrs, Connecticut 06269, USA.
Abstract:
Experimental investigations of solid materials at elevated temperatures rely on the optimized thermal design of the measurement system, as radiation becomes a predominant source of heat loss which can lead to large uncertainty in measured temperature and related physical properties of a test sample. Advancements in surface temperature measurements have reduced thermal losses arising from the cold-finger effect using axially inserted thermocouples and from radiation using shields or other thermal guards. The leading technology for temperature sensing at temperatures up to ∼900 °C makes use of these design features for measuring thermopower, yet uncertainty analysis estimation of this technique is not known. This work makes use of finite element modeling to determine spatial temperature distributions to obtain the upper limit of confidence expected for the axially inserted thermocouple approach when a heated radiation shield is incorporated into the design. Using an axially inserted thermocouple to measure the sample surface temperature, the temperature variations across the sample hot and cold surfaces at 900 °C for a temperature drop of 0, 5, and 10 °C are calculated to be as low as 0.02, 0.21, and 0.41 °C, respectively, when a heated radiation shield is employed. Uniform temperature distribution on the thermocouple cross-wire geometry indicates that the axial thermocouple measurement design is indeed effective for suppressing the cold-finger effect. Using a heated radiation shield is found to significantly reduce the temperature gradient across the thermocouples.
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Uncertainty in Measurement: Significant Figures
Uncertainty in Measurement: Accuracy and Precision
The Uncertainty Principle
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...