Proper Cut-off Levels of Serum Specific IgE to Cefaclor for Patients with Cefaclor Allergy
Young Hee Nam1, So Hee Lee2, Hyo In Rhyou1
1Department of Internal Medicine, College of Medicine, Dong-A University, Busan, Korea.
Purpose:
Cefaclor, a second-generation oral cephalosporin, is known to cause IgE-mediated hypersensitivity. Assays of serum-specific IgE (sIgE) to cefaclor are commercially available via the ImmunoCAP system (Thermo Fisher Scientific). While serum levels of sIgE >0.35 kU/L are considered indicative of an allergy, some patients with cefaclor allergy show low serum IgE levels. This study aimed to evaluate the proper cut-off levels of sIgE in the diagnosis of immediate hypersensitivity to cefaclor.
Materials And Methods:
A total of 269 patients with drug allergy history, who underwent assays of sIgE to cefaclor at Ajou University hospital and Dong-A University Hospital, were reviewed retrospectively. Among them, 193 patients exhibited cefaclor-induced immediate hypersensitivity with certain or probable causality of an adverse drug reaction according to the WHO-UMC (the World Health Organization-the Uppsala Monitoring Centre) algorithm, and 76 controls showed delayed hypersensitivity reactions to non-antibiotics.
Results:
In total, 126 of the 193 patients (65.3%) experienced anaphylaxis; they had higher serum sIgE levels than patients with immediate hypersensitivity who did not experience anaphylaxis (6.36±12.39 kU/L vs. 4.28±13.61 kU/L, p<0.001). The best cut-off value for cefaclor-induced immediate hypersensitivity was 0.11 kU/L, with sensitivity of 80.2% and specificity of 81.6%. A cut-off value of 0.44 kU/L showed the best sensitivity (75.4%) and specificity (65.7%) for differentiating anaphylaxis from immediate hypersensitivity reactions.
Conclusion:
Patients with cefaclor anaphylaxis exhibit high serum IgE levels. A cut-off value of 0.11 kU/L of sIgE to cefaclor is proper for identifying patients with cefaclor allergy, and 0.44 kU/L may be useful to detect anaphylaxis.
Related Concept Videos
Overview of Connective Tissues Proper
The loose connective tissues have a meshwork of thin collagen and elastin fibers, which provide tensile strength for support and enough elasticity to move...
Layers of Connective Tissue Proper
Allergic Reactions
Cut-off Frequency of BJT
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
Brick Cutting Techniques
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
Leveling Effect