Related Experiment Video
Updated: Feb 5, 2026

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Comparison of Er,Cr:YSGG Laser Handpieces for Class II Preparation and Microleakage of Silorane- or
Esra Ergin1, Fatma Dilsad Oz1, Sevil Gurgan1
1Department of Restorative Dentistry, Faculty of Dentistry, Hacettepe University , Ankara, Turkey .
Objective:
The aim of this study was to evaluate the influence of cavity preparation with different Er,Cr:YSGG laser handpieces on microleakage of different posterior composite restorations.
Methods:
Fifty-four extracted intact human premolars were randomly assigned to three groups according to cavity preparation method: Bur Group: high-speed diamond bur (Diatech), MD Group: Er,Cr:YSGG laser Waterlase MD handpiece (Biolase Millennium II), and Turbo Group: Er,Cr:YSGG laser Waterlase MD TURBO handpiece (Biolase Millennium II). One hundred eight Class II slot cavities were prepared on the mesial and distal proximal surfaces of each tooth, and the cavity preparation times required were determined. The groups were then subdivided according to the restorative systems used (n = 12): a conventional methacrylate-based microhybrid composite (Filtek P60+Adper Single Bond 2/3M); a silorane-based resin composite (Filtek Silorane+Silorane System Adhesive/3M); and a nanohybrid methacrylate-based composite (Kalore+G-Bond/GC). The restorative systems were applied according to the manufacturers' recommendations. Following thermocycling (X5000; 5°C-55°C), the teeth were coated with nail varnish except the restoration margins, immersed in 0.5% basic fuchsin dye solution, and sectioned in a mesiodistal direction. Dye penetration was evaluated under a light microscope for occlusal and cervical margins. Data were analyzed with one-way ANOVA and chi-square tests (p < 0.05).
Results:
The cavity preparation time (mean ± SD) required for Bur, MD, and Turbo group was 31.25 ± 3.82, 222.94 ± 15.85, and 92.5 ± 7.42 sec, respectively, and the differences among the groups were statistically significant (p < 0.05). Comparing the occlusal and cervical microleakage scores, no statistically significant differences were found among the groups and subgroups (p > 0.05).
Conclusions:
Er;Cr:YSGG laser cavity preparation with the Turbo handpiece needed shorter time than the MD handpiece, although it needed longer time than the conventional diamond bur. The use of different handpieces of Er,Cr:YSGG laser did not differ from conventional preparation with diamond bur in terms of microleakage with the tested methacrylate- and silorane-based posterior composite restorative systems.
More Related Videos
Related Concept Videos
Restorative Care
Solution Composition During Acid/Base Titrations
The α0 and α1 values...
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Drug Classes and Categories
Antibody Structure and Classes
The basic structure of an antibody consists of four protein chains: two identical heavy chains and two identical light chains. These chains are held together by disulfide bonds and other non-covalent interactions, forming a Y-shaped structure.