Meta-analysis indicates that add-on devices and new endoscopes reduce colonoscopy adenoma miss rate
Paraskevas Gkolfakis1, Georgios Tziatzios1, Antonio Facciorusso2
1Hepatogastroenterology Unit, Second Department of Internal Medicine-Propaedeutic, Research Institute and Diabetes Center, Medical School, National and Kapodistrian University of Athens, Attikon University General Hospital, Athens, Greece.
Introduction:
A variety of add-on devices and new-generation endoscopes have the potential to detect lesions 'hidden' behind colonic folds. We measured the effect of these new modalities on colonoscopy's lesions miss rates by a meta-analysis of data from individual studies.
Materials And Methods:
We performed literature searches in Medline and Cochrane Library for back-to-back randomized-controlled trials evaluating colonoscope add-on devices and new endoscopes in terms of lesions miss rates. The effect size on study outcomes is shown as relative risk (95% confidence interval).
Results:
We identified nine tandem studies with 1594 patients: seven evaluating add-on devices (one with cap, two with Endocuff, one with Endorings, one with Third-Eye Retroscope, two with G-EYE endoscope) and two evaluating the full-spectrum endoscopy system (FUSE) in comparison with conventional colonoscopy (CC). Overall, adenoma miss rate (AMR) was significantly lower with add-on devices/FUSE [0.33 (0.22-0.50), P<0.00001] compared with CC, the effect being similar among the add-on devices [0.35 (0.22-0.57), P<0.0001] and the FUSE [0.26 (0.15-0.46), P<0.00001] studies, respectively. Advanced AMR and polyp miss rate (PMR) were also significantly lower using add-on devices/FUSE [0.30 (0.21-0.44), P<0.0001 and 0.31 (0.13-0.79), P=0.01, respectively]. Use of add-on devices/FUSE scope was associated with significantly lower AMR and PMR in the proximal colon and it was associated with shortening of the colonoscopy surveillance interval.
Conclusion:
Our meta-analysis provides evidence that AMR, advanced AMR, and PMR are significantly lower using add-on to colonoscope devices and the full-spectrum endoscopy systems compared with CC. Heterogeneity among the included studies and the small number of detected advanced adenomas call for cautious interpretation of the results.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
04:34Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
Published on: February 17, 2023
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Directing Effect of Substituents: meta-Directing Groups
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Related Rates
Speciation Rates