Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Noninvasive Monitoring of Dynamic Cerebrovascular Autoregulation and 'Optimal Blood Pressure' in Normal Adult
Paul Pham1, Jessica Bindra1, Anders Aneman1,2
1South Western Sydney Clinical School, University of New South Wales, Locked Bag 7103, Liverpool BC, NSW, 1871, Australia.
Background:
Cerebrovascular autoregulation can be continuously monitored from slow fluctuations of arterial blood pressure (ABP) and regional cerebral oxygen saturation (rSO2). The purpose of this study was to evaluate the index of dynamic cerebrovascular autoregulation (TOx) and the associated 'optimal' ABP in normal adult healthy subjects.
Methods:
Twenty-eight healthy volunteers were studied. TOx was calculated as the moving correlation coefficient between spontaneous fluctuations of ABP and rSO2. ABP was measured with the Finometer photoplethysmograph. The ABP with optimal autoregulation (ABPOPT) was also determined as the ABP level with the lowest associated TOx (opt-TOx).
Results:
Average rSO2 and TOx was 72.3 ± 2.9% and 0.05 ± 0.18, respectively. Two subjects had impaired autoregulation with a TOx > 0.3. The opt-TOx was - 0.1 ± 0.26. ABPOPT was 87.0 ± 16.7 mmHg. The difference between ABP and ABPOPT was - 0.3 ± 7.5 mmHg. In total, 44% of subjects had a deviation of ABP from ABPOPT exceeding 5 mmHg. ABPOPT ranged from 57 to 117 mmHg.
Conclusions:
TOx in healthy volunteers on average displays intact autoregulation and ABP close to ABPOPT. However, some subjects have possible autoregulatory dysfunction or a significant deviation of ABP from ABPOPT, which may confer a susceptibility to neurological injury.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.