Related Experiment Video
Updated: Feb 5, 2026

Author Spotlight: Advancing Pathogen Diagnostics with Standardized LAMP
Published on: September 8, 2023
Development of Visual Detection of α-Thalassemia-1 (the - -SEA Deletion) Using pH-Sensitive Loop-Mediated Isothermal
Sirinart Chomean1, Kanokporn Pholyiam1, Areenuch Thamwarokun1
1a Department of Medical Technology, Faculty of Allied Health Science s, Thammasat University , Klong Luang , Pathum Thani Province , Thailand.
Abstract:
Detection of α-thalassemia-1 (α-thal-1) carriers provides valuable insight for genetic consulting in prevention and control programs for couples who are at risk of conceiving a fetus with severe thalassemia, both Hb Bart's hydrops fetalis and hemolytic Hb H disease. The traditional method is complicated, time-consuming and requires high instrument cost and expertise. Loop-mediated isothermal amplification (LAMP) based on pH-sensitive dye technology, shows all the characteristics required of a real-time analysis with simple operation for potential use in the clinical diagnosis of high incidence α-thal-1 [Southeast Asian (SEA) or - -SEA deletion]. Four primers specific for six distinct regions of the α-globin gene deletion were designed and analyzed by LAMP using the pH-indicator dye, phenol red. The amplification of the - -SEA deletion changed the color of phenol red from pink to orange. The diagnostic ability of detection of the - -SEA deletion by pH-sensitive LAMP was validated using both known and unknown blood samples and compared to the conventional polymerase chain reaction (PCR) method. Color inspection of pH-sensitive LAMP products could clearly identify the - -SEA deletion. There was no cross reaction with a normal α-globin gene, α-thal-1 Thai (- -THAI deletion), α-thal-2 [-α3.7 (rightward) and -α4.2 (leftward) deletion] and β-thalassemia (β-thal). Detection of the SEA deletion by pH-sensitive LAMP was consistent as compared to conventional PCR. The pH-sensitive LAMP method developed for this deletion carrier diagnosis has high sensitivity, specificity, simplicity, and requires simple instrumentation that makes it applicable for resource-limited laboratories in rural areas of developing countries.
Related Concept Videos
Piaget's Stage 1 of Cognitive Development
Exploration...
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Feedback Loops
RACE - Rapid Amplification of cDNA Ends
Receptor-mediated Endocytosis

