Background:
Anterior load carriage represents a common daily and occupational activity. Carrying loads in front of the body could potentially increase instability during standing and walking.
Research Question:
This study examined the effects of anterior load carriage on postural sway and gait parameters in healthy adults.
Methods:
Twenty-nine participants (19 males, 10 females, age = 33.8 ± 12.7 years, height = 1.73 ± 0.07 m, mass = 75.1 ± 13.7 kg) were assessed in four conditions; (1) carrying no load (CON), (2) carrying a load with no added weight (i.e. empty box), (3) carrying a load with 5% body mass, and (4) carrying a load with 10% body mass. Anteroposterior and mediolateral centre of pressure (COP) displacement (cm) and the mean COP velocity (cm s-1) were used to characterise postural sway. Coefficient of variation of the stride length, stride time and double support time were calculated from 1 min of treadmill walking at a preferred pace for gait assessment.
Results:
The addition of the 10% load elicited an increase in anteroposterior COP displacement when compared to CON (d = 1.59), 0% (d = 1.50), and 5% (d = 0.75) (P < 0.001). The addition of the 10% load increased stride time (d = 1.71) and stride length (d = 1.20) variability when compared to CON (P < 0.001).
Significance:
In summary, the increase in postural sway and gait variability with added weight is dependent on the magnitude of the load, where the greater the load, the greater the effect on static and dynamic stability. Anterior load carriage potentially increases the risk of fall-related injuries.
More Related Videos
06:21Postural Organization of Gait Initiation for Biomechanical Analysis Using Force Platform Recordings
Published on: July 26, 2022
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
Related Concept Videos
Timing and Consequences on Behavior
Humans, however, can respond to delayed reinforcers. We often make decisions between immediate small rewards and delayed larger rewards. This ability to delay gratification is a significant...
Characteristics of Life
Characteristics of Fluids
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
Characteristics of JFET
The core of a JFET's operation is controlling drain current by modulating the gate-source voltage. When the drain and gate voltage are set to zero, the JFET exhibits no net current flow, representing a state of equilibrium. The drain current increases linearly as the...