The effect of transcranial magnetic stimulation test intensity on the amplitude, variability and reliability of motor evoked potentials
Related Experiment Video
Updated: Feb 5, 2026

Stimulating the Lip Motor Cortex with Transcranial Magnetic Stimulation
Published on: June 14, 2014
Michael Pellegrini1, Maryam Zoghi2, Shapour Jaberzadeh1
1Non-Invasive Brain Stimulation and Neuroplasticity Laboratory, Department of Physiotherapy, School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Science, Monash University, Melbourne, Australia.
Abstract:
High degrees of variability reported in Transcranial magnetic stimulation (TMS) assessment of corticospinal excitability (CSE) highlight the need to investigate its reliability as an assessment tool. This study investigated the effect of TMS test intensity on the amplitude, variability and test-retest reliability of motor evoked potentials (MEP). Twenty-five MEPs were recorded at 105%, 120%, 135%, 150% and 165% of resting motor threshold across three sessions in twelve participants. Repeated measures analysis of variance (RM-ANOVA), recruitment curve gradients and standardised z-value SDs were utilized to investigate the effect of TMS test intensity on MEP amplitude and variability. Test-retest reliability of MEP amplitude was assessed using RM-ANOVA and intraclass correlations (ICC). RM-ANOVA reported MEP amplitude significantly increased between 105-120% and 120-135% with non-significant increases thereafter. Recruitment curve gradients reduced as TMS test intensity increased. Standardised z-value SDs reported MEP amplitude variability reduced as TMS test intensity increased with the only significant reduction occurring between 120% and 135%. RM-ANOVA reported no significant effect of time on MEP amplitude, indicating agreement between sessions. ICCs indicated significant intra- and inter-session reliability for all TMS test intensities except for 105%. The only significant reduction in variability and final significant increase in MEP amplitude occurred between the same TMS test intensities. Reduced variability and increased reliability at higher TMS test intensities validate the use of higher TMS test intensities to assess changes in CSE in future research. To increase accuracy in capturing true changes in CSE we recommend assessing changes in CSE across a range of TMS test intensities.
Related Concept Videos
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Reliability and Validity
Magnetic Vector Potential
Consider an ideal solenoid with n turns per unit length and radius R. If I is the current through the solenoid, the magnetic field inside the solenoid is expressed as the product of vacuum...
Potential Due to a Magnetized Object
The vector...
Action Potential: Phases of Stimulation
Resting Phase:
In this phase, the cell's membrane is at its resting potential, typically around -70 millivolts (mV) for neurons. Inside the cell, there is a higher concentration of potassium ions (K+) and a lower concentration of sodium ions (Na+). Voltage-gated sodium channels are closed, and...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...

