Measurements of Diffusion and Perfusion in Vertebral Bone Marrow Using Intravoxel Incoherent Motion (IVIM) With
Jérémy Lasbleiz1, Caroline Le Ster1,2, Raphaël Guillin3
1Univ Rennes, Inserm, LTSI - UMR 1099, F-35000, Rennes, France.
Background:
A limited number of studies have used the intravoxel incoherent motion (IVIM) approach on bone marrow. In none of the previous studies were the effects of fat suppression on the IVIM parameters investigated.
Purpose:
To measure the water diffusion coefficient and the perfusion fraction in vertebral bone marrow using IVIM with multishot, readout-segmented (RESOLVE) echo-planar imaging and to assess the effects of different fat suppression techniques on the measurement of the IVIM parameters.
Study Type:
Prospective.
Population/Subjects:
Six healthy volunteers (24.2 ± 4.3 years).
Field Strength/Sequence:
1.5T, RESOLVE.
Assessment:
Four experiments were performed: 1) RESOLVE imaging without fat suppression, 2) with fat saturation (FS), 3) with spectral attenuated inversion recovery (SPAIR), and 4) with short-tau inversion recovery (STIR). The water diffusion coefficient D, pseudo-diffusion coefficient D*, and the perfusion fraction f were assessed in the vertebral bodies of the lumbar vertebrae.
Statistical Tests:
One-way repeated-measures analysis of variance (ANOVA) followed by Bonferroni's multiple comparison test.
Results:
The RESOLVE IVIM protocol allowed for measurement of D, D*, and f in all volunteers. The signal of lipid protons affected the quantification of the IVIM diffusion coefficient: D = 0.24 ± 0.10 (×10-3 mm2 /s), no FS; D = 0.43 ± 0.07 (×10-3 mm2 /s), FS; D = 0.42 ± 0.07 (×10-3 mm2 /s), SPAIR; D = 0.35 ± 0.10 (×10-3 mm2 /s), STIR; and IVIM perfusion fraction f = 7.5 ± 1.9% no FS, f = 14.5 ± 5.4%, FS; f = 12.5 ± 2.6%, SPAIR; f = 18.1 ± 6.1%, STIR. No significant effect (P = 0.36) was found on the quantification of D*.
Data Conclusion:
An IVIM-MRI protocol using the RESOLVE sequence was implemented for measurements of vertebral bone marrow diffusion and the perfusion. The comparison between the protocols with and without fat suppression indicates that the lipid signal results in an underestimation of both D and f.
Level Of Evidence:
Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;49:768-776.
Related Concept Videos
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Bone Marrow Sampling and Transplants
The transplant begins with high doses of chemotherapy and radiation treatment, which aim to destroy...
Diffusion
Diffusion