Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Automatic Processing and Automatic Social Behavior01:28

Automatic Processing and Automatic Social Behavior

258
Automatic processing refers to the cognitive operations that occur without conscious intent or awareness, playing a fundamental role in shaping social cognition and behavior. These processes enable individuals to navigate complex social environments efficiently by relying on mental shortcuts and pre-existing knowledge structures known as schemas. One of the most influential mechanisms underlying automatic processing is priming, which subtly activates mental representations through exposure to...
258
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

7.0K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
7.0K
Detection of Black Holes01:10

Detection of Black Holes

2.6K
Although black holes were theoretically postulated in the 1920s, they remained outside the domain of observational astronomy until the 1970s.
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
2.6K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

8.4K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.4K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

667
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
667
Types of Errors: Detection and Minimization01:12

Types of Errors: Detection and Minimization

11.4K
Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
11.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Antibodies against influenza A/H1N1pdm2009 and B/Victoria strains but not A/H3N2 are increased in recent onset type 1 narcolepsy versus matched controls.

medRxiv : the preprint server for health sciences·2026
Same author

Cytology and <i>KRAS/GNAS</i> Molecular Testing of Pancreatic Cyst Fluid for Risk Stratification of Intraductal Papillary Mucinous Neoplasms: A Single-Center Study with Histological Correlation.

Journal of clinical medicine·2026
Same author

Protocol for the DREAMER study: Design and methodological framework of a multicenter trial-ready cohort of individuals with isolated REM sleep without atonia.

PloS one·2026
Same author

Clinical outcomes of rehabilitation with a robotic anthropomorphic exoskeleton in patients with motor-incomplete spinal cord injury: a multicenter randomized controlled trial.

European journal of physical and rehabilitation medicine·2026
Same author

Clinical markers of disease progression in the prodromal to overt alpha-synucleinopathy continuum.

Brain : a journal of neurology·2026
Same author

To diagnose Narcolepsy type 1 after a negative Multiple Sleep Latency Test: the contribution of systematic hypocretin measurement.

Sleep·2026
Same journal

Dim light melatonin onset profile endotypes in a real-world clinical population with home-based, self-collected salivary assessments: Identification, distribution, and potential clinical relevance.

Sleep medicine·2026
Same journal

Non-rapid eye movement parasomnias and sleep quality among medical students: Implications for academic performance: A cross-sectional survey.

Sleep medicine·2026
Same journal

Ten-year trends in pediatric hypnotic prescribing before and during the COVID-19 pandemic in Japan.

Sleep medicine·2026
Same journal

Corrigendum to "Efficacy and safety of tonic motor activation (TOMAC) for restless legs syndrome as adjunctive and monotherapy: An individual participant data systematic review and meta-analysis" [Sleep Med. 140 (2026) 108810].

Sleep medicine·2026
Same journal

Sleep disturbances in patients with vasculitis.

Sleep medicine·2026
Same journal

Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry.

Sleep medicine·2026
See all related articles

Related Experiment Video

Updated: Feb 5, 2026

Automatic Detection of Highly Organized Theta Oscillations in the Murine EEG
09:35

Automatic Detection of Highly Organized Theta Oscillations in the Murine EEG

Published on: March 10, 2017

9.7K

Automatic detection of cataplexy.

Ilaria Bartolini1, Fabio Pizza2, Andrea Di Luzio3

  • 1Department of Computer Science and Engineering, University of Bologna, Bologna, Italy.

Sleep Medicine
|September 9, 2018
PubMed
Summary
This summary is machine-generated.

This study shows automatic video analysis can detect cataplexy, a key symptom of narcolepsy type 1, with 81% accuracy. This technology offers a promising tool to improve narcolepsy diagnosis.

Keywords:
Automatic video analysisCataplexyLaughterNarcolepsyVideo recording

More Related Videos

Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples
04:57

Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples

Published on: April 25, 2025

1.1K
Automatic Separation and Collection of Cancer-Related Substances from Clinical Samples
08:49

Automatic Separation and Collection of Cancer-Related Substances from Clinical Samples

Published on: January 13, 2023

2.3K

Related Experiment Videos

Last Updated: Feb 5, 2026

Automatic Detection of Highly Organized Theta Oscillations in the Murine EEG
09:35

Automatic Detection of Highly Organized Theta Oscillations in the Murine EEG

Published on: March 10, 2017

9.7K
Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples
04:57

Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples

Published on: April 25, 2025

1.1K
Automatic Separation and Collection of Cancer-Related Substances from Clinical Samples
08:49

Automatic Separation and Collection of Cancer-Related Substances from Clinical Samples

Published on: January 13, 2023

2.3K

Area of Science:

  • Neurology
  • Sleep Medicine
  • Biomedical Engineering

Background:

  • Cataplexy is the most specific symptom of narcolepsy type 1 (NT1), but diagnosis relies solely on clinical interviews, posing potential diagnostic challenges.
  • Current diagnostic methods for cataplexy lack objective measures, leading to potential inaccuracies.

Purpose of the Study:

  • To evaluate the accuracy of an automated video detection system for cataplexy in NT1 patients compared to non-cataplectic individuals.
  • To assess the feasibility of using SHIATSU (Semantic-based HIearchical Automatic Tagging of videos by Segmentation using cUts) for objective cataplexy detection.

Main Methods:

  • Fifteen drug-naive NT1 patients and 15 non-cataplectic controls underwent standardized video recording with emotional stimulation.
  • Videos were analyzed by human experts for typical cataplexy facial motor patterns and by the SHIATSU system.
  • The performance of automatic detection was compared against expert assessments.

Main Results:

  • All NT1 patients exhibited cataplexy during emotional stimulation, while none of the controls did.
  • The automated SHIATSU system achieved an 81% overall accuracy in detecting cataplexy in NT1 patients compared to human experts.
  • A 13.3% false positive rate was observed in non-cataplectic subjects due to active eye closure mimicking ptosis.

Conclusions:

  • Automated video detection of cataplexy using SHIATSU is feasible and shows significant accuracy (81%) compared to human examiners.
  • Further research is needed to expand the range of detected motor patterns and quantify cataplexy for improved diagnostic utility.
  • This technology holds potential for more objective and reliable diagnosis of narcolepsy type 1.