Related Experiment Video
Updated: Feb 5, 2026

Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty
Published on: September 17, 2014
Avoiding Hyperopic Surprises After Descemet Membrane Endothelial Keratoplasty in Fuchs Dystrophy Eyes by Assessing
Marianne Fritz1, Viviane Grewing1, Daniel Böhringer1
1Eye Center, University Medical Center Freiburg, Freiburg, Germany.
Purpose:
It is unclear which patients unexpectedly have a hyperopic refractive outcome after combined Descemet membrane endothelial keratoplasty and cataract surgery (triple DMEK). We assessed how corneal shape predicts hyperopia after triple DMEK.
Design:
Retrospective cohort study.
Methods:
Patients with Fuchs endothelial corneal dystrophy (FECD) with Scheimpflug examinations before uncomplicated triple DMEK at a tertiary referral center were included. The arithmetic error was calculated (stable postoperative refraction minus predicted refraction). Using multinomial logistic regression, risk ratios of > +0.5 diopter (D) hyperopic and > 0.5 D myopic arithmetic errors were calculated.
Results:
In 112 eyes, the median predicted refraction was -0.43 D (interquartile range [IQR], -0.47 to -0.17) with an achieved refraction of -0.63 to 0.56 (IQR). The arithmetic error was 0.34 D (IQR, -0.22 to 0.81). A hyperopic arithmetic error was present in 46% of eyes. FECD eyes with an oblate posterior cornea (Q value >0) had a 3.0 times higher risk of hyperopic shift after triple DMEK (95% confidence interval [CI], 1.3-7.0; P = .011), compared to spherical or prolate corneas (Q value ≤ 0). In eyes with posterior Q > 0, the mean prediction error was +0.50 D higher than in eyes with negative Q values (95% CI, 0.19-0.82; P = .002), independent of corneal thickness.
Conclusions:
Hyperopic surprises after triple DMEK particularly occur in corneas that are flatter centrally than the periphery because of edematous changes (oblate posterior profile). Eyes with a positive Q value on Scheimpflug imaging should be considered for additional power at the intraocular lens level.
Related Concept Videos
Frustration and Conflict: Avoidance-Avoidance, Double-Approach Avoidance
Molecular Shape and Polarity
Satellite Stem Cells and Muscular Dystrophy
VSEPR Theory and the Basic Shapes
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Molecular Shapes
Two regions of electron density in a diatomic...