Quantification of temporal resolution improvement factor in SMART-RECON based time-resolved C-arm Cone beam computed
John W Garrett1,2, Yinsheng Li1, Ke Li1,2
1Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI 53705, United States of America.
None:
In a recently published paper by Li et al (2018 Phys. Med. Biol. 63 075001), reconstruction parameters were optimized for the so-called synchronized multiArtifact reduction with tomographic reconstruction (SMART-RECON) method to enable time-resolved Cone beam computed tomography angiography (TR-CBCTA) from a single short-scan CBCT data set. However, the paper did not quantitatively address how much temporal resolution can be improved by using the SMART-RECON algorithm in TR-CBCTA. The purpose of this note was to present a method to quantify this temporal resolution improvement factor and to use that method to quantify the improvement in temporal resolution using SMART-RECON and optimized reconstruction parameters. In the method proposed in this note, the potential temporal blurring caused by SMART-RECON was modeled as a convolution between a temporal Gaussian blurring kernel and the ground truth temporal enhancement curve. The width parameter of the resulting Gaussian blurring kernel was used as a surrogate metric for temporal resolution to quantify the achievable temporal resolution for the conventional filtered backprojection (FBP) and SMART-RECON methods. The ratio of the surrogate temporal resolutions for the two reconstruction methods was calculated to quantify the factor of temporal resolution improvement. The quantitative results show that the temporal resolution is improved by a factor of 4.5 using SMART-RECON compared with FBP.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Imaging Studies III: Computed Tomography
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...