Related Experiment Video
Updated: Feb 5, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Conventional versus computer-assisted surgery in total knee arthroplasty: comparison at ten years follow-up
Michele d'Amato1, Andrea Ensini1,2, Alberto Leardini2
1Department of Orthopaedic Surgery, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136, Bologna, Italy.
Purpose:
Computer-assisted systems (CAS) for total knee arthroplasty (TKA) were expected to result in more accurate prosthesis implantation, better patient outcomes, and longer implant survival when compared to conventional instrumentation (CI). The aim of this study was to compare two groups of patients operated using CAS or CI at ten years follow-up.
Methods:
One hundred twenty TKA patients, 60 using CAS and 60 using CI, were contacted after a decade for follow-up. Eligible patients received radiological examination to assess the lower-limb mechanical axis. They were also clinically assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Knee Society Score for Knee (KSS-K) and Function (KSS-F) Scoring. Kaplan-Meier survival analysis was performed to assess revisions, not for post-traumatic reasons.
Results:
In CAS and CI groups, the lower-limb mechanical axis was 1.7° ± 2.4° and 1.5° ± 2.8°, respectively; corresponding KOOS values were 82.3 ± 14.3 and 78.6 ± 14.4; KSS-K values were 85.9 ± 11.1 and 85.0 ± 9.7; KSS-F values were 82.2 ± 19.3 and 83.8 ± 18. For these assessments, the differences between the two groups were not statistically significant (p > 0.05). Two CAS (3.8%) and three CI patients (5.7%) were revised. The Kaplan-Meier analysis showed no significant differences between the two groups.
Conclusions:
No significant differences were found at long-term follow-up in terms of radiographical-clinical outcomes and of implant survival between TKA operated using CAS or CI.
Related Concept Videos
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Enolate Mechanism Conventions
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons

