Related Experiment Video
Updated: Feb 5, 2026

Construction and Characterization of External Cavity Diode Lasers for Atomic Physics
Published on: April 24, 2014
[Research on the Distribution of Gas Concentration of Two-Dimensional Reconstruction Based on Tunable Diode Laser
Abstract:
The two-dimensional concentration distribution was reconstructed by using algebraic iterative reconstruction algorithm. This paper mainly focused on the effects of multispectral H2O absorptions on condition that the laser beam was less and the temperature was known, i.e. the influence of temperature on spectral line-strength was not considered as to this concentration distribution. Based on ART algorithm, increased spectral lines and increased laser beam were compared under the same concentration model. Three H2O lines were selected to reconstruct two-dimensional distribution of non-uniform gas concentration, and these three transitions were selected within the external cavity diode laser turning range in the simulated system. The interested region was discretized to 10×10 grid points, and the temperature and concentration of the reconstruction model were not evenly distributed, so the unimodal distribution and bimodal distribution were used to describe the concentration distribution. The simulated system also calculated the effective utilization of laser beams and absorption lines. The results showed that the reconstruction quality quickly increased with increasing H2O absorption lines when the laser beams were very few, the increased absorption lines could get more spectral information related to the concentration. The increased laser beam is also effective to improve the accuracy of reconstruction results, but increasing the absorption lines can better reconstruct a two-dimensional concentration distribution. Improving the absorption lines can also effectively reduce the costs of the hardware and the complexity of the measurement system, which shows that the multispectral absorption lines are applicable to in-situ measurements.
More Related Videos
08:50Total Internal Reflection Absorption Spectroscopy TIRAS for the Detection of Solvated Electrons at a Plasma-liquid Interface
Published on: January 24, 2018
07:55Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Molecular Spectroscopy: Absorption and Emission
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Spectroscopy: Absorption, Emission, and Fluorescence