Related Experiment Video
Updated: Feb 5, 2026

Designing Silk-silk Protein Alloy Materials for Biomedical Applications
Published on: August 13, 2014
Origin of low Young modulus of multicomponent, biomedical Ti alloys - Seeking optimal elastic properties through a
P Kwasniak1, J S Wróbel1, H Garbacz1
1Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Woloska 141, 02-507 Warsaw, Poland.
Abstract:
Multicomponent, biomedical β-Ti alloys offer ultra-low Young modulus values that are related to a unique and poorly understood reduction of C44 and C' elastic constants in comparison with binary systems. The elastic properties of such materials are difficult to control due to the large variations occurring even for a small change in chemical composition, which cannot be explained using existing theories. In this article, we investigate the above issues through systematic ab initio elastic constants calculations for a series of binary, ternary and quaternary Ti alloys. Special attention is paid to examining the reliability of the methodology adopted and to clarifying the atomic scale mechanisms that affect the mechanical properties of the systems analysed. It was found that the lower boundary of the polycrystalline Young modulus of Ti-Nb-base β phase is close to 50 GPa, and strongly depends on two specific electronic hybridisations related to niobium and simple metals addition that control C44 and C'. Based on the relationship established between electronic structure and mechanical properties, we propose several quaternary alloys whose directional <100> Young modulus values are equal or similar to that of human bones. Some electronic-based guidelines for designing new multicomponent β-Ti alloys are also formulated.
Related Concept Videos
Strain and Elastic Modulus
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
The Uncertainty Principle
Bulk Modulus
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...

