Related Experiment Video
Updated: Feb 5, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Determination of glyoxal and methylglyoxal in atmospheric fine particulate matter by vortex-assisted micro-solid
1National University of Singapore Environmental Research Institute, National University of Singapore, T-Lab Building #02-01, 5A Engineering Drive 1, Singapore 117411, Singapore.
Abstract:
Determination of α-dicarbonyl compounds, glyoxal (Gly) and methyl glyoxal (Mgly), in atmospheric fine particulate matter PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 μm) which play vital roles in generating secondary organic aerosols in the ambient air, was carried out by vortex-assisted micro-solid phase extraction (VA-μ-SPE)-liquid chromatography-diode array detection (LC-DAD), with on-sorbent derivatization by 2,4-dinitrophenylhydrazine (DNPH). This is the first time such an approach of combining on-sorbent derivatization and extraction in one step together with LC analysis has been applied to PM2.5. Extraction parameters such as selection of sorbent, extraction time, desorption time and sample volume were optimized using water samples spiked with Gly and Mgly. Under the most favourable conditions, good intra- (1.39%-2.78%) and inter-day (2.29%-6.56%) precision and linearity (ranging between 0.5 and 100 ng mL-1) along with coefficients of determination 0.998 and 0.997, were determined. The limits of detection were determined to be 0.14 ng mL-1 (derivatized Gly) and 0.15 ng mL-1 (derivatized Mgly) whereas the limits of quantification were 0.47 ng mL-1 and 0.50 ng mL-1, respectively. The developed method was successfully employed to the determination of Gly and Mgly associated with PM2.5. The latter was collected on glass fiber filters which were immersed in methanol: water (1:1 v/v) for μ-SPE, which was conducted using a sorbent pre-coated with DNPH. The concentrations of the Gly and Mgly were determined to be 0.38 ng m-3 and 0.41 ng m-3 in the sampled ambient air, with relative recoveries of between 69-97%.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Molecular Comparison of Gases, Liquids, and Solids
States of Matter and Phase Changes
Classifying Matter by State
Speed of Sound in Solids and Liquids
Physical and Chemical Properties of Matter
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: